Warning
titleWARNING

The NORMAL-DEFAULT state does not include any selective downlink (instrument is not in SBM_DETECTION mode). The "DefaultDEFAULT-SCIENCE" state for the SBM_DETECTION mode is given in RPW_SCIENCE DETECTION-DEFAULT.

Description

This section gives more details about the NORMAL-DEFAULT state. The latter can be set with the sequences AIWF037A (THR), AIWF038E (TDS), AIWF039D (LFR)The instrument is in the SCIENCE SURVEY_NORMAL submode and in the "DEFAULT-SCIENCE" configuration.

The "StateMode" section gives the general state software mode of the sub-system (i.e. , S/W mode). The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this state. The "Attributes" section lists the TC and/or formal parameters values for , which can change the resource allocation related to this state.

DPU setting

Mode

...