The formal definition of the QUALITY_BITMASK CDF zVariable is provided in the "Metadata Definition for Solar Orbiter Science Data" document (SOL-SGS-TN-0009). There is one value per CDF record.
For RPW L1 CDF
The QUALITY_BITMASK values of the RPW L1 CDFs are set by the RPW operations and data pipeline (RODP) hosted at LESIA.
Table below gives the list of possible values for L1 CDFs. It assumes that this values are common to all RPW L1 CDF products (TBC).
The QUALITY_BITMASK values of the RPW L1 CDFs are set by the RPW operations and data pipeline (RODP) hosted at LESIA.
Bit | Decimal value | Meaning | Justification | Computation | Comment |
RPW +Z ANT PA in the line of sight of the HGA during TX ON. | The HGA TX may have an impact on the RPW science measurement quality when the ANT PA in the HGA light of sight | To be determinated by ROC from SPICE computation | |||
SPICE Heat Shield Door is open | SPICE HSD may have an impact on the RPW +Z ANT bending effect | Known from HSD_SPICE_OPEN E-FECS event | |||
LFR setting has changed before the end of the current data samples acquisition | According to LFR data acquisition mechanism and CDF structure, it can be impossible for some dataset (i.e., SWF) to take of a LFR setting change - performed via a command execution on-board - in a CDF record time window. Users need nevertheless to be warned when such LFR setting change occurred during a data sample acquisition. | Known from the reception of the TM_LFR_TC_EXE_SUCCESS {YIW00139} S1 TM that confirms the LFR setting change | |||
Possible SWA-PAS high voltage contamination | SWA-PAS unit may provoke noise on RPW measurements | Inclusion of this event into the bitmask is TBC (quantification of the impact is TBD) | |||
EMC QUIET window | SolO payload is in EMC QUIET mode | Known from EMC_MAND_QUIET E-FECS event | |||
EMC NOISY window | SolO payload is in EMC QUIET mode | Known from EMC_PREF_NOISY E-FECS event | |||
Spacecraft roll manœuvre | Indicate when the spacecraft perform rolls | Known from *_ROLL E-FECS event | |||
Thruster firings | Indicate when the plateform thruster firings happen | Known from TMC+WOL E-FECS event | |||
BIAS1_SWEEP - ongoing sweep | Ongoing sweep on one probe. | Should be set from 100 ms before the sweep to 1 s after the sweep on a particular probe. | |||
BIAS2_SWEEP - ongoing sweep | |||||
BIAS3_SWEEP - ongoing sweep | |||||
BIAS1_CURRENT_NONCONSTANT | Changes in biasing current may (1) not be instantaneous, and (2) may have uncertain timestamps. | Should be set from 100 ms before to 1 s after any change in bias current on a particular probe (including sweeps). | |||
BIAS2_CURRENT_NONCONSTANT | |||||
BIAS3_CURRENT_NONCONSTANT | |||||
SCM out of working temperature | Indicate when the SCM temperature are out of working range | known from HK_LFR_TEMP_SCM T< -55°C or T> +85°C | |||
EMC Transients ? | indicate EMC transient: - SCM heater on/off - autre ..? | - Known from HK_PDU_HEATER_CURRENT - autre .. ? | |||
SCM calibration on | Indicate when the LFR send calibvration signal to SCM | known from HK_LFR_CALIB_ENABLED |
For RPW L2 CDF
Table below gives the list of possible values for L2 CDF.
The QUALITY_BITMASK values of the RPW L2 CDF will be set by the RPW Calibration Software (RCS).
Bits allocated at L1 level should be saved as is in L2 and not superseded. Free bits can be used by the RCS to provide extra information.
Table below gives the list of possible values to be set in L2 CDF by RCS.
INSTRUCTION: Table to be filled with extra information to be passed by RCS in the L2 CDF QUALITY_BITMASK zVar using free bits. "Bit" and "Decimal value" columns should be let free for the moment. "Comment" column can be used to specify the data L2 CDF product(s) for which the QUALITY_BITMASK zVar must be set (if it is not specified, it is assumed that all L2 CDF products requires this information).
Bit | Decimal value | Meaning | Justification | Computation | Comment |
...