Bit | Decimal value | Meaning | Justification | Computation | Comment | ||||||||
RPW +Z ANT PA in the line of sight of the HGA during TX ON. | The HGA TX may have an impact on the RPW science measurement quality when the ANT PA in the HGA light of sight | To be determinated by ROC from SPICE computation | |||||||||||
SPICE Heat Shield Door is open | SPICE HSD may have an impact on the RPW +Z ANT bending effect | Known from HSD_SPICE_OPEN E-FECS event | |||||||||||
LFR setting has changed before the end of the current data samples acquisition | According to LFR data acquisition mechanism and CDF structure, it can be impossible for some dataset (i.e., SWF) to take of a LFR setting change - performed via a command execution on-board - in a CDF record time window. Users need nevertheless to be warned when such LFR setting change occurred during a data sample acquisition. | Known from the reception of the TM_LFR_TC_EXE_SUCCESS {YIW00139} S1 TM that confirms the LFR setting change | |||||||||||
Possible SWA-PAS high voltage contamination | SWA-PAS unit may provoke noise on RPW measurements | Inclusion of this event into the bitmask is TBC (quantification of the impact is TBD) | |||||||||||
EMC QUIET window | SolO payload is in EMC QUIET mode | Known from EMC_MAND_QUIET E-FECS event | |||||||||||
EMC NOISY window | SolO payload is in EMC QUIET mode | Known from EMC_PREF_NOISY E-FECS event | |||||||||||
Spacecraft roll manœuvre | Indicate when the spacecraft perform rolls | Known from *_ROLL E-FECS event | |||||||||||
Thruster firings | Indicate when the plateform thruster firings happen | Known from TMC+WOL E-FECS event | |||||||||||
BIAS1_SWEEP - ongoing sweep | Ongoing sweep on one probe. | Should be set from 100 ms before the sweep to 1 s after the sweep on a particular probe. | |||||||||||
BIAS2_SWEEP - ongoing sweep | |||||||||||||
BIAS3_SWEEP - ongoing sweep | |||||||||||||
BIAS1_CURRENT_NONCONSTANT | Changes in biasing current may (1) not be instantaneous, and (2) may have uncertain timestamps. | Should be set from 100 ms before to 1 s after any change in bias current on a particular probe (including sweeps). | |||||||||||
BIAS2_CURRENT_NONCONSTANT | |||||||||||||
BIAS3_CURRENT_NONCONSTANT | SCM out of working temperature | Indicate when the SCM temperature are out of working range | known from HK_LFR_TEMP_SCM T< -55°C or T> +85°CEMC Transients ? | indicate EMC transient: - SCM heater on/off - autre ..? | - Known from HK_PDU_HEATER_CURRENT - autre .. ? | SCM calibration on | Indicate when the LFR send calibvration signal to SCM | known from HK_LFR_CALIB_ENABLED | |||||
For RPW L2 CDF
The QUALITY_BITMASK values of the RPW L2 CDF will be set by the RPW Calibration Software (RCS).
...
Bit | Decimal value | Meaning | Justification | Computation | Comment |
SCM out of working temperature | Indicate when the SCM temperature are out of working range | known from HK_LFR_TEMP_SCM T< -55°C or T> +85°C | |||
EMC Transients ? | indicate EMC transient: - SCM heater on/off - autre ..? | - Known from HK_PDU_HEATER_CURRENT - autre .. ? | |||
SCM calibration on | Indicate when the LFR send calibvration signal to SCM | known from HK_LFR_CALIB_ENABLED | |||
RPW QUALITY_FLAG CDF VARIABLE
...