Hereafter the number (6) and frequencies expected from  the PCDU APRs DC/DC Converters (data from frequency plan provided by ADS).


APR#1 DC/DC Converter (~120 kHz)

117,6

Not Xtal

~84Hz/degC. For a 5 degC variation over 1 hour, Δf/f=0.3%; during  TVAC frequency drift  <100 ppm/h for  4 degC variation of PCDU temperature

APR#2 DC/DC Converter (~120 kHz)

118,4

Not Xtal

~84Hz/degC. For a 5 degC variation over 1 hour, Δf/f=0.3%; during  TVAC frequency drift  <100 ppm/h for  4 degC variation of PCDU temperature

APR#3 DC/DC Converter (~120 kHz)

119,3

Not Xtal

~84Hz/degC. For a 5 degC variation over 1 hour, Δf/f=0.3%; during  TVAC frequency drift  <100 ppm/h for  4 degC variation of PCDU temperature

APR#4 DC/DC Converter (~120 kHz)

120,7

Not Xtal

~84Hz/degC. For a 5 degC variation over 1 hour, Δf/f=0.3%; during  TVAC frequency drift  <100 ppm/h for  4 degC variation of PCDU temperature

APR#5 DC/DC Converter (~120 kHz)

121

Not Xtal

~84Hz/degC. For a 5 degC variation over 1 hour, Δf/f=0.3%; during  TVAC frequency drift  <100 ppm/h for  4 degC variation of PCDU temperature

APR#6 DC/DC Converter (~120 kHz)

121,1

Not Xtal

~84Hz/degC. For a 5 degC variation over 1 hour, Δf/f=0.3%; during  TVAC frequency drift  <100 ppm/h for  4 degC variation of PCDU temperature

...