Description of the RPW Science Default Configuration (DefCon)_SCIENCE NORMAL-DEFAULT configuration.
...
Context and purpose
The RPW Science Default Configuration (DefCon) RPW_SCIENCE NORMAL-DEFAULT is the main operating science configuration for SURVEY_NORMAL mode, to be applied on-board during the Solar Orbiter science operations.
The DefCon corresponds to the "default state" as requested by the MOC.
The requirements relative to this config. are:
- The DefConf must be invariant over the RPW Software SCIENCE modes (i.e., SURVEY_NORMAL, SURVEY_BURST, SBM_DETECTION)
Description
RPW
RPW is ON. in SCIENCE mode.
DPU
DPU is started with DAS in SCIENCE mode.
THR
TBW
LFR
TBW
TDS
TBW
BIAS
TBW
SCM
TBW
ANT
TBW
DefConf free attributes
TBW
Open issues
...
Description
The instrument is in the SCIENCE SURVEY_NORMAL submode and in the "DEFAULT-SCIENCE" configuration.
The "Mode" section gives the software mode of the sub-system. The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this configuration. The "Attributes" section lists the TC and/or formal parameters values, which can change the resource allocation related to this configuration.
DPU setting
Mode
DPU is started with DAS in SCIENCE SURVEY_NORMAL mode.
Configuration
Associated sequences
- AIWF032A
- AIWF032B
- AIWF032C
- AIWF032D
- AIWF032E
- AIWF032F
- AIWF032G
- AIWF032H
- AIWF032I
- AIWF032J
- AIWF032K
Attributes
TC packet | Description | Default value |
---|---|---|
TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION | Waveform packet compression activation/deactivation | N/A |
THR setting
Mode
THR is started in SCIENCE SURVEY_NORMAL mode.
Configuration
This configuration is the default configuration, or "Direction-Finding" config. The measurement time is 12 seconds.
Associated sequences
- AIWF037A
- AIWF037C
Attributes
TC packet / TC parameters | Description | Default value |
---|---|---|
LFR setting
Mode
LFR is started in SCIENCE SURVEY_NORMAL mode.
Configuration
Associated sequences
- AIWF039C
- AIWF039D
Attributes
TC packet / TC parameters | Description | Default value |
---|---|---|
TDS
Mode
TDS is started in SCIENCE SURVEY_NORMAL mode.
Configuration
1D histo:
- Xaxis: LOG_HIST_64
- Yaxis: PEAK_W_AMP, RMS_W_AMP, RMS_S_AMP, MAXAMP_CH1
2D histo:
- Xaxis: LOG_HIST_128
- Yaxis: HISTA_32
- Zaxis: DA_VS_RE
Associated sequences
- AIWF038A
- AIWF038E
Attributes
TC packet / TC parameters | Description | Default value |
---|---|---|
BIAS setting
Mode
Bias unit is ON
Configuration
TBW
Associated sequences
- AIWF040A
Attributes
SCM setting
SCM is ON
ANT setting
ANT PA are ON
Resources allocation
Telemetry
- With compression: 4.584 kbps
- Without compression: 6.7454 kbps
Power consumption
- Hot case: 17.7W