Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Description of the RPW Science Default Configuration (DefCon)_SCIENCE NORMAL-DEFAULT configuration.

...

Context and purpose

The RPW Science Default Configuration (DefCon) RPW_SCIENCE NORMAL-DEFAULT is the main operating science configuration for SURVEY_NORMAL mode, to be applied on-board during the Solar Orbiter science operations.

Description

The DefCon corresponds to the "default state" as requested by the MOC.

The requirements relative to this config. are:

  • The DefConf must be invariant over the RPW Software SCIENCE modes (i.e., SURVEY_NORMAL, SURVEY_BURST, SBM_DETECTION)

Description

This section gives details about the DefCon. Especially, the list of free/fixed parameters are reported for each analyser.

RPW state

RPW is ON.

instrument is in the SCIENCE SURVEY_NORMAL submode and in the "DEFAULT-SCIENCE" configuration.

The "Mode" section gives the software mode of the sub-system. The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this configuration. The "Attributes" section lists the TC and/or formal parameters values, which can change the resource allocation related to this configuration.

DPU setting

Mode

...

DPU is started with DAS in SCIENCE SURVEY_NORMAL mode.

Configuration

Associated sequences

  • AIWF032A
  • AIWF032B
  • AIWF032C
  • AIWF032D
  • AIWF032E
  • AIWF032F
  • AIWF032G
  • AIWF032H
  • AIWF032I
  • AIWF032J
  • AIWF032K

Attributes

TC packet
TC / TC parameters
Description
Value
Default value
Fixed

TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION

Waveform packet compression activation/deactivationN/A

THR setting

...

THR state

TBW

LFR state

...

TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION

Mode

THR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

This configuration is the default configuration, or "Direction-Finding" config. The measurement time is 12 seconds.

Image Added

Associated sequences

  • AIWF037A
  • AIWF037C

Attributes

TC packet / TC parametersDescriptionDefault value




LFR setting

Mode

LFR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Image Added

Associated sequences

  • AIWF039C
  • AIWF039D

Attributes

TC packet / TC parametersDescriptionDefault value




TDS

Mode

TDS is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Image Added

1D histo:

  • Xaxis: LOG_HIST_64
  • Yaxis: PEAK_W_AMP, RMS_W_AMP, RMS_S_AMP, MAXAMP_CH1 

2D histo:

  • Xaxis: LOG_HIST_128
  • Yaxis: HISTA_32
  • Zaxis: DA_VS_RE

Associated sequences

  • AIWF038A
  • AIWF038E

Attributes

TC packet / TC parametersDescriptionDefault value





BIAS setting

Mode

Bias unit is ON

Configuration

TBW

Associated sequences

  • AIWF040A

Attributes

SCM setting

SCM is ON

ANT setting

ANT PA are ON

Resources allocation

Telemetry

  • With compression: 4.584 kbps
  • Without compression: 6.7454 kbps

Power consumption

  • Hot case: 17.7W
  • Cold case: 19.1W

Open issues

TDS

TBW

BIAS

TBW

SCM

TBW

ANT

TBW

DefConf free attributes

TBW

Open issues

...