Description of the RPW_SCIENCE NORMAL-DEFAULT Configurationconfiguration.
...
Context and purpose
The RPW_SCIENCE NORMAL-DEFAULT Configuration is the main operating science configuration for SURVEY_NORMAL mode, to be applied on-board during the Solar Orbiter science operations.
This config. corresponds to the "default state" as requested by the MOC.
Description
This section gives details about the Config.
Description
The instrument is in the SCIENCE SURVEY_NORMAL submode and in the "DEFAULT-SCIENCE" configuration.
The "ModeThe "State" section gives the general state software mode of the sub-system (i.e., S/W mode). The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this configuration. The "Attributes" section lists the TC and/or formal parameters values, which are allowed to change the config..
RPW general configuration
State
RPW is ON.
Attributes
N/A
DPU configuration
can change the resource allocation related to this configuration.
DPU setting
Mode
...
DPU is started with DAS in SCIENCE SURVEY_NORMAL mode.
Configuration
Associated sequences
- AIWF032A
- AIWF032B
- AIWF032C
- AIWF032D
- AIWF032E
- AIWF032F
- AIWF032G
- AIWF032H
- AIWF032I
- AIWF032J
- AIWF032K
Attributes
TC packet | Description | Default value |
---|---|---|
TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION | Waveform packet compression activation/deactivation | N/A |
THR
...
setting
...
Mode
THR is started in SCIENCE SURVEY_NORMAL mode.
Configuration
This configuration is the default configuration, or "Direction-Finding" config. The measurement time is 12 seconds.
Associated sequences
- AIWF037A
- AIWF037C
Attributes
TC packet / TC parameters | Description | Default value |
---|---|---|
LFR
...
setting
...
Mode
LFR is started in SCIENCE SURVEY_NORMAL mode.
Configuration
Associated sequences
- AIWF039C
- AIWF039D
Attributes
TC packet / TC parameters | Description | Default value |
---|---|---|
TDS
...
Mode
TDS is started in SCIENCE SURVEY_NORMAL mode.
Configuration
1D histo:
- Xaxis: LOG_HIST_64
- Yaxis: PEAK_W_AMP, RMS_W_AMP, RMS_S_AMP, MAXAMP_CH1
2D histo:
- Xaxis: LOG_HIST_128
- Yaxis: HISTA_32
- Zaxis: DA_VS_RE
Associated sequences
- AIWF038A
- AIWF038E
Attributes
TC packet / TC parameters | Description | Default value |
---|---|---|
BIAS setting
...
Mode
Bias unit is ON
Configuration
TBW
Associated sequences
- AIWF040A
Attributes
SCM setting
State
SCM is ON
ANT setting
State
ANT PA are ON
Resources allocation
Telemetry
- With compression: 4.584 kbps
- Without compression: 6.7454 kbps
Power consumption
- Hot case: 17.7W
- Cold case: 19.1W