Description of the RPW_SCIENCE NORMAL-DEFAULT Configurationconfiguration.

...

Context and purpose

The RPW_SCIENCE NORMAL-DEFAULT Configuration is the main operating science configuration for SURVEY_NORMAL mode, to be applied on-board during the Solar Orbiter science operations.

This config. corresponds to the "default state" as requested by the MOC.

Description

Description

The instrument is in the SCIENCE SURVEY_NORMAL submode and in the "DEFAULT-SCIENCE" configurationThis section gives more details about the Config. The NORMAL-DEFAULT config. is triggered by the IW-FCP-040 procedure.

The "StateMode" section gives the general state software mode of the sub-system (i.e. , S/W mode). The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this configuration. The "Attributes" section lists the TC and/or formal parameters values, which are allowed to change the config..

RPW general configuration

State

RPW is ON.

Attributes

N/A

DPU configuration

...

can change the resource allocation related to this configuration.

DPU setting

Mode

DPU is started with DAS in SCIENCE SURVEY_NORMAL mode.

Configuration

Associated sequences

  • AIWF032A
  • AIWF032B
  • AIWF032C
  • AIWF032D
  • AIWF032E
  • AIWF032F
  • AIWF032G
  • AIWF032H
  • AIWF032I
  • AIWF032J
  • AIWF032K

Attributes

TC packetDescriptionDefault value

TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION

Waveform packet compression activation/deactivationN/A

THR

...

setting

...

Mode

THR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

This configuration is the default configuration, or "Direction-Finding" config. The measurement time is 12 seconds.

Associated sequences

  • AIWF037A
  • AIWF037C

Attributes

TC packet / TC parametersDescriptionDefault value




LFR

...

setting

...

Mode

LFR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Associated sequences

  • AIWF039C
  • AIWF039D

Attributes

TC packet / TC parametersDescriptionDefault value




TDS

...

Mode

TDS is started in SCIENCE SURVEY_NORMAL mode.

Configuration

1D histo:

  • Xaxis: LOG_HIST_64
  • Yaxis: PEAK_W_AMP, RMS_W_AMP, RMS_S_AMP, MAXAMP_CH1 

...

  • Xaxis: LOG_HIST_128
  • Yaxis: HISTA_32
  • Zaxis: DA_VS_RE

Associated sequences

  • AIWF038A
  • AIWF038E

Attributes

TC packet / TC parametersDescriptionDefault value





BIAS setting

...

Mode

Bias unit is ON

Configuration

TBW

Associated sequences

  • AIWF040A

Attributes

SCM

...

setting

SCM is ON

ANT setting

State

ANT PA are ON

Resources allocation

Telemetry

  • With compression: TBD 4.584 kbps
  • Without compression:  TBD 6.7454 kbps

Power consumption

  • Hot case: 17.7W
  • Cold case: 19.1W

...