Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Table below gives the list of possible values for L1 CDFs. It assumes that these values are common to all RPW L1 CDF products.

NOTE: E-FECS events are defined in https://s2e2.cosmos.esa.int/confluence/display/SOSP/Solar+Orbiter+Enhanced+Flight+Events+Communications+Skeleton+%28EFECS%29+ICD 

Bit Decimal  valueMeaningJustificationComputationComment
01BIAS1_SWEEP - ongoing sweepOngoing sweep on ANT1 probeShould be set from 100 ms before the sweep to 1 s after the sweep on a particular probe.First bit (LSB)
12BIAS2_SWEEP - ongoing sweepOngoing sweep on ANT2 probe

243BIAS3_SWEEP - ongoing sweepOngoing sweep on ANT3 probe

348EMC QUIET windowSolO payload is in EMC QUIET modeKnown from EMC_MAND_QUIET E-FECS event 
4516EMC NOISY windowSolO payload is in EMC NOISY modeKnown from EMC_PREF_NOISY E-FECS event
5632Spacecraft roll manœuvreIndicate when the spacecraft perform rolls or slewsKnown from *_ROLL and SLEW E-FECS event
6647Thruster firingsIndicate when the plateform thruster firings happen Known from TMC+WOL E-FECS event


RPW +Z ANT PA in the line of sight of the HGA during TX ON.The HGA TX may have an impact on the RPW science measurement quality when the ANT PA in the HGA light of sight To be determinated by ROC from SPICE computationNot implemented


SPICE Heat Shield Door is openSPICE HSD may have an impact on the RPW +Z ANT bending effectKnown from HSD_SPICE_OPEN E-FECS eventNot implemented


LFR setting has changed before the end of the current data samples acquisitionAccording to LFR data acquisition mechanism and CDF structure, it can be impossible for some dataset (i.e., SWF) to take of a LFR setting change - performed via a command execution on-board - in a CDF record time window. Users need nevertheless to be warned when such LFR setting change occurred during a data sample acquisition. Known from the reception of the TM_LFR_TC_EXE_SUCCESS {YIW00139} S1 TM that confirms the LFR setting change Not implemented


Possible SWA-PAS high voltage contaminationSWA-PAS unit may provoke noise on RPW measurementsInclusion of this event into the bitmask is TBC (quantification of the impact is TBD)Not implemented


BIAS1_CURRENT_NONCONSTANTChanges in biasing current may (1) not be instantaneous, and (2) may have uncertain timestamps.Should be set from 100 ms before to 1 s after any change in bias current on a particular probe (including sweeps).Not implemented


BIAS2_CURRENT_NONCONSTANT




BIAS3_CURRENT_NONCONSTANT




















...