Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Description of the RPW_SCIENCE NORMAL-DEFAULT Stateconfiguration.

...

Context and purpose

The RPW_SCIENCE NORMAL-DEFAULT State is the main operating science state configuration for SURVEY_NORMAL mode, to be applied on-board during the Solar Orbiter science operations.

This state corresponds to the "default state" as requested by the MOC.

Warning
titleWARNING

The NORMAL-DEFAULT state does not include any selective downlink (instrument is not in SBM_DETECTION mode). The "Default" state for the SBM_DETECTION mode is given in RPW_SCIENCE DETECTION-DEFAULT.

Description

This section gives more details about the NORMAL-DEFAULT state. The latter can be set with the sequences AIWF037A (THR), AIWF038E (TDS), AIWF039D (LFR).

Description

The instrument is in the SCIENCE SURVEY_NORMAL submode and in the "DEFAULT-SCIENCE" configuration.

The "Mode" section gives the software mode The "State" section gives the general state of the sub-system (i. e., S/W mode). The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this configuration. The "Attributes" section lists the TC and/or formal parameters values for this state, which can change the resource allocation related to this configuration.

DPU setting

Mode

DPU is started with DAS in SCIENCE SURVEY_NORMAL mode.

Configuration

Associated sequences

  • AIWF032A
  • AIWF032B
  • AIWF032C
  • AIWF032D
  • AIWF032E
  • AIWF032F
  • AIWF032G
  • AIWF032H
  • AIWF032I
  • AIWF032J
  • AIWF032K

Attributes

TC packetDescriptionDefault value

TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION

Waveform packet compression activation/deactivationN/A

...

This configuration is the default configuration, or "Direction-Finding" config. The measurement time is 12 seconds.

Associated sequences

  • AIWF037A
  • AIWF037C

Attributes

TC packet / TC parametersDescriptionDefault value




...

LFR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Associated sequences

  • AIWF039C
  • AIWF039D

Attributes

TC packet / TC parametersDescriptionDefault value




...

  • Xaxis: LOG_HIST_128
  • Yaxis: HISTA_32
  • Zaxis: DA_VS_RE

Associated sequences

  • AIWF038A
  • AIWF038E

Attributes

TC packet / TC parametersDescriptionDefault value




...

Bias unit is ON

Configuration

TBW

Associated sequences

  • AIWF040A

Attributes

SCM setting

SCM is ON

...