About the RPW TNR-HFR galaxy configuration._SCIENCE NORMAL-GALAXY configuration

...

Context & Purpose

The RPW TNR-HFR Galaxy _SCIENCE NORMAL-GALAXY configuration gives the priority to the measurement of the galaxy background by the TNR-HFR sub-system.

Description

RPW

RPW is ON. in SCIENCE mode.

The instrument is set in the SURVEY_NORMAL SCIENCE submode with the "galaxy" configuration.

The "Mode" section gives the software mode of the sub-system. The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this configuration. The "Attributes" section lists the TC and/or formal parameters values, which can change the resource allocation related to this configuration.

DPU setting

Mode

...

DPU is started with DAS in SCIENCE mode.

THR

TBD

LFR

N/A

TDS

N/A

BIAS

N/A

SCM

N/A

ANT

N/A

...

SURVEY_NORMAL submode.

Configuration

TBW

Associated sequences

TBW

Attributes

TBW

THR setting

Mode

THR is ON in the SURVEY_NORMAL submode.

Configuration

Image Added

Associated sequences

TBW

Attributes

TC packet / FP valueDescriptionValue

TBD

Spectral AVG sampling time in seconds20
7.5


LFR setting

Mode

LFR is OFF

Configuration

N/A

Associated sequences

TBW

Attributes

TBW

TDS setting

Mode

TDS is OFF

Configuration

N/A

Associated sequences

TBW

Attributes

TBW

BIAS setting

Mode

Bias unit is OFF

Configuration

TBW

Associated sequences

TBW

Attributes

TBW


SCM setting

SCM PA are ON

ANT setting

ANT PA are ON

Resources allocation

Telemetry

  • With Spect. AVG sampling rate of 20s: 0.48 kbps
  • With Spect. AVG sampling rate of 7.5s: 1.0 kbps

Power consumption

  • Hot case: 17.7W (TBC)
  • Cold case: 19.1W (TBC)