Description of the RPW Science Default Configuration (DefCon).

RPW Science Default Configuration (DefCon) description

_SCIENCE NORMAL-DEFAULT configuration.

...

Context and purpose

RPW_SCIENCE NORMAL-DEFAULT The RPW Science Default Configuration (DefCon) is the main operating science configuration for SURVEY_NORMAL mode, to be applied on-board during the Solar Orbiter science operations.

The DefCon corresponds to the "default state" as requested by the MOC.

The requirements relative to this state are:

  • The DefConf must be invariant over the RPW Software SCIENCE modes (i.e., SURVEY_NORMAL, SURVEY_BURST, SBM_DETECTION)

DefConf fixed attributes

RPW

RPW is ON. in SCIENCE mode.

DPU

DPU is started with DAS in SCIENCE mode.

THR

TBW

LFR

TBW

TDS

TBW

BIAS

TBW

SCM

TBW

ANT

TBW

DefConf free attributes

TBW

Open issues

...

.

Description

The instrument is in the SCIENCE SURVEY_NORMAL submode and in the "DEFAULT-SCIENCE" configuration.

The "Mode" section gives the software mode of the sub-system. The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this configuration. The "Attributes" section lists the TC and/or formal parameters values, which can change the resource allocation related to this configuration.

DPU setting

Mode

DPU is started with DAS in SCIENCE SURVEY_NORMAL mode.

Configuration

Associated sequences

  • AIWF032A
  • AIWF032B
  • AIWF032C
  • AIWF032D
  • AIWF032E
  • AIWF032F
  • AIWF032G
  • AIWF032H
  • AIWF032I
  • AIWF032J
  • AIWF032K

Attributes

TC packetDescriptionDefault value

TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION

Waveform packet compression activation/deactivationN/A

THR setting

Mode

THR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

This configuration is the default configuration, or "Direction-Finding" config. The measurement time is 12 seconds.

Image Added

Associated sequences

  • AIWF037A
  • AIWF037C

Attributes

TC packet / TC parametersDescriptionDefault value




LFR setting

Mode

LFR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Image Added

Associated sequences

  • AIWF039C
  • AIWF039D

Attributes

TC packet / TC parametersDescriptionDefault value




TDS

Mode

TDS is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Image Added

1D histo:

  • Xaxis: LOG_HIST_64
  • Yaxis: PEAK_W_AMP, RMS_W_AMP, RMS_S_AMP, MAXAMP_CH1 

2D histo:

  • Xaxis: LOG_HIST_128
  • Yaxis: HISTA_32
  • Zaxis: DA_VS_RE

Associated sequences

  • AIWF038A
  • AIWF038E

Attributes

TC packet / TC parametersDescriptionDefault value





BIAS setting

Mode

Bias unit is ON

Configuration

TBW

Associated sequences

  • AIWF040A

Attributes

SCM setting

SCM is ON

ANT setting

ANT PA are ON

Resources allocation

Telemetry

  • With compression: 4.584 kbps
  • Without compression: 6.7454 kbps

Power consumption

  • Hot case: 17.7W
  • Cold case: 19.1W