You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

Description of the RPW_SCIENCE DETECTION-DEFAULT State.


Context and purpose

The RPW_SCIENCE DETECTION-DEFAULT state is the main operating science state for SBM_DETECTION mode, to be applied on-board during the Solar Orbiter science operations.

Description

This section gives more details about the state. The SBM1/SBM2 parametrization of the DETECTION-DEFAULT state can be set using the specifc sequences AIWF038B, AIWF038C (TDS) and AIWF039A, AIWF039B (TDS) with formal parameter default values.

The "State" section gives the general state of the sub-system (i.e., S/W mode). The "configuration" section gives the detailed configuration of the sub-system. The "Attributes" section lists the TC and/or formal parameters which are allowed to change the configuration.

DPU setting

Mode

DPU is started with DAS in SCIENCE SBM_DETECTION mode.

Configuration

Same than RPW_SCIENCE NORMAL-DEFAULT

Associated sequences

Same than RPW_SCIENCE NORMAL-DEFAULT

Attributes

TC packetDescriptionDefault value

TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION

Waveform packet compression activation/deactivationN/A

THR setting

Mode

THR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Same than RPW_SCIENCE NORMAL-DEFAULT

Associated sequences

Same than RPW_SCIENCE NORMAL-DEFAULT

Attributes

TC packet / TC parametersDescriptionDefault value




LFR setting

Mode

LFR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Associated sequences

For the SURVEY_NORMAL mode, same than RPW_SCIENCE NORMAL-DEFAULT

Specific to SBM1/SBM2 detection configuration:

  • AIWF039A
  • AIWF039B

Attributes

TC packet / TC parametersDescriptionDefault value




TDS setting

Mode

TDS is started in SCIENCE SURVEY_NORMAL mode.

Configuration

1D histo:

  • Xaxis: LOG_HIST_64
  • Yaxis: PEAK_W_AMP, RMS_W_AMP, RMS_S_AMP, MAXAMP_CH1 

2D histo:

  • Xaxis: LOG_HIST_128
  • Yaxis: HISTA_32
  • Zaxis: DA_VS_RE

Associated sequences

For the SURVEY_NORMAL mode, same than RPW_SCIENCE NORMAL-DEFAULT

Specific to SBM1/SBM2 detection configuration:

  • AIWF038B
  • AIWF038C

Attributes

TC packet / TC parametersDescriptionDefault value




BIAS setting

Mode

Bias unit is ON

Configuration

Same than RPW_SCIENCE NORMAL-DEFAULT

Associated sequences

Same than RPW_SCIENCE NORMAL-DEFAULT

Attributes

N/A

SCM setting

SCM is ON

ANT setting

ANT PA are ON

Resources allocation

Telemetry

  • With compression: 7.774 kbps (SURVEY_NORMAL data contribution) + SBM1/SBM2
  • Without compression: 5.1054 kbps (SURVEY_NORMAL data contribution)

Power consumption

  • Hot case: 17.7W
  • Cold case: 19.1W
  • No labels