Description of the RPW_SCIENCE DETECTION-DEFAULT configuration.
RPW_SCIENCE DETECTION-DEFAULT is the main operating science configuration for SBM_DETECTION mode, to be applied on-board during the Solar Orbiter science operations.
The instrument is in the SCIENCE SBM_DETECTION submode and in a specific science-default configuration.
The "Mode" section gives the software mode of the sub-system. The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this state. The "Attributes" section lists the TC and/or formal parameters values, which can change the resource allocation related to this state.
DPU is started with DAS in SCIENCE SBM_DETECTION mode.
Same than RPW_SCIENCE NORMAL-DEFAULT
Same than RPW_SCIENCE NORMAL-DEFAULT
TC packet | Description | Default value |
---|---|---|
TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION | Waveform packet compression activation/deactivation | N/A |
THR is started in SCIENCE SURVEY_NORMAL mode.
Same than RPW_SCIENCE NORMAL-DEFAULT
Same than RPW_SCIENCE NORMAL-DEFAULT
TC packet / TC parameters | Description | Default value |
---|---|---|
LFR is started in SCIENCE SURVEY_NORMAL mode.
For the SURVEY_NORMAL mode, same than RPW_SCIENCE NORMAL-DEFAULT
Specific to SBM1/SBM2 detection configuration:
TC packet / TC parameters | Description | Default value |
---|---|---|
TDS is started in SCIENCE SURVEY_NORMAL mode.
1D histo:
2D histo:
For the SURVEY_NORMAL mode, same than RPW_SCIENCE NORMAL-DEFAULT
Specific to SBM1/SBM2 detection configuration:
TC packet / TC parameters | Description | Default value |
---|---|---|
Bias unit is ON
Same than RPW_SCIENCE NORMAL-DEFAULT
Same than RPW_SCIENCE NORMAL-DEFAULT
N/A
SCM is ON
ANT PA are ON