This page gives the content of the RPW CRP-000.
TM Parameters:
We have 13 RPW TM parameters that are in OCF table and can trigger an OOL. None of those have a Spacon action assigned. This automatically means: "Call on-call SOE"
TM Packets:
PID_TYPE | PID_STYPE | PID_APID | PID_PI1_VAL | PID_PI2_VAL | PID_SPID | PID_DESCR | SpaconAction |
5 | 2 | 1207 | 42101 | 0 | 55032 | ADC failure (Erroneous data, loss of data, data can't be read). | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42102 | 0 | 55033 | DPU AHB correctable error (memory corruption detected by EDAC). | To be ignored, always no action. |
5 | 2 | 1207 | 42107 | 0 | 55034 | PDU link timeout error. | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42108 | 0 | 55035 | Spacecraft link timeout error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42113 | 0 | 55036 | PDU SiS interface failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42114 | 0 | 55037 | Spacecraft SpaceWire interface error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42118 | 0 | 55038 | DPU Time anomaly (timecode inconsistent, not synchronized). | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42126 | 0 | 55039 | DPU Timecode anomaly (timecode missing, invalid). | If less than 5 events are received in a reporting in a day, then no action Else: Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42127 | 0 | 55040 | A software reset has been requested by TC. | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 3 | 1207 | 42302 | 0 | 55041 | DPU AHB uncorrectable error (memory corruption detected by EDAC) | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42306 | 0 | 55042 | EEPROM failure (write, timeout). | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42307 | 0 | 55043 | DPU memory load operation fails. | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 3 | 1207 | 42314 | 0 | 55044 | PDU SiS interface failure (read / write invalid address). | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42315 | 0 | 55045 | Spacecraft SpaceWire interface error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42319 | 0 | 55046 | Boot Error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42331 | 0 | 55047 | DBS buffer overflow. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42351 | 0 | 55048 | Missing or corrupted configuration parameter block. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42511 | 0 | 55049 | Permanent ADC failure (too many errors have occurred. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42503 | 0 | 55051 | PDU link fatal error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42509 | 0 | 55052 | Unexpected DPU reset. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42115 | 0 | 55100 | LFR SpaceWire low severity error detected. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42116 | 0 | 55101 | TDS SpaceWire low severity error detected. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42117 | 0 | 55102 | THR SpaceWire low severity error detected. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42122 | 0 | 55103 | LFR RMAP error (general error code, invalid key, early EOP...). | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42123 | 0 | 55104 | TDS RMAP error (general error code, invalid key, early EOP...). | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42124 | 0 | 55105 | THR RMAP error (general error code, invalid key, early EOP...). | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42125 | 0 | 55106 | RPW current consumption warning. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42112 | 0 | 55107 | BIA SiS interface failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42106 | 0 | 55108 | BIA link timeout error. | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42137 | 0 | 55109 | Error during compression process. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 2 | 1207 | 42109 | 0 | 55110 | LFR link error. | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42110 | 0 | 55111 | TDS link error. | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 2 | 1207 | 42111 | 0 | 55112 | THR link error. | Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email! |
5 | 3 | 1207 | 42316 | 0 | 55113 | LFR SpaceWire medium severity error detected. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42317 | 0 | 55114 | TDS SpaceWire medium severity error detected. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42318 | 0 | 55115 | THR SpaceWire medium severity error detected. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42323 | 0 | 55116 | LFR permanent error (too many RMAP errors). | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42324 | 0 | 55117 | TDS permanent error (too many RMAP errors). | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42325 | 0 | 55118 | THR permanent error (too many RMAP errors). | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42329 | 0 | 55120 | RPW current consumption alarm. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42320 | 0 | 55121 | LFR Boot Error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42321 | 0 | 55122 | TDS Boot Error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42322 | 0 | 55123 | THR Boot Error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42313 | 0 | 55124 | BIA SiS interface failure (read / write invalid address). | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42337 | 0 | 55125 | DAS buffer overflow. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42344 | 0 | 55126 | Communication error with LFR. | The generation of this event is expected upon execution of TCs from Remarks section. In this case, log as "expected due to ddddd" in the daily report. Otherwise call engineer (during working hours) |
5 | 3 | 1207 | 42346 | 0 | 55127 | Communication error with TDS. | The generation of this event is expected upon execution of TCs from Remarks section. In this case, log as "expected due to ddddd" in the daily report. Otherwise call engineer (during working hours) |
5 | 3 | 1207 | 42348 | 0 | 55128 | Communication error with THR. | The generation of this event is expected upon execution of TCs from Remarks section. In this case, log as "expected due to ddddd" in the daily report. Otherwise call engineer (during working hours) |
5 | 3 | 1207 | 42326 | 0 | 55129 | LFR command execution failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42327 | 0 | 55130 | TDS command execution failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42328 | 0 | 55131 | THR command execution failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42332 | 0 | 55132 | DPU mode transition failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42333 | 0 | 55133 | LFR mode transition failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42334 | 0 | 55134 | TDS mode transition failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42335 | 0 | 55135 | THR mode transition failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42352 | 0 | 55136 | PDU operation failure (switch on failed, switch off failed). | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42508 | 0 | 55137 | RPW temperature critical alarm. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42502 | 0 | 55139 | BIA link fatal error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42504 | 0 | 55140 | LFR link fatal error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42505 | 0 | 55141 | TDS link fatal error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42506 | 0 | 55142 | THR link fatal error. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42353 | 0 | 55429 | Too many time anomalies have consecutively occurred. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42336 | 0 | 55434 | Service 20 packet no more received. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42515 | 0 | 55436 | BIAS high voltage failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42516 | 0 | 55437 | Overcurrent on RPW equipment. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42354 | 0 | 55443 | BIAS sweeping failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42355 | 0 | 55450 | BIAS calibration failure. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 3 | 1207 | 42356 | 0 | 55451 | A delayed mode transition has been aborted. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
5 | 4 | 1207 | 42517 | 0 | 55472 | Over-voltage detected. | Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!! |
Commands:
We have 139 RPW commands. Each one of them have the same action in case it fails execution ---> "Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report"