This page gives the content of the RPW CRP-000.



TM Parameters:
We have 13 RPW TM  parameters that are in OCF table and can trigger an OOL. None of those have a Spacon action assigned. This automatically means: "Call on-call SOE"
 
TM Packets:

PID_TYPE

PID_STYPE

PID_APID

PID_PI1_VAL

PID_PI2_VAL

PID_SPID

PID_DESCR

SpaconAction

5

2

1207

42101

0

55032

ADC failure (Erroneous data, loss of data, data can't be read).Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42102

0

55033

DPU AHB correctable error (memory corruption detected by EDAC).To be ignored, always no action.

5

2

1207

42107

0

55034

PDU link timeout error.Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42108

0

55035

Spacecraft link timeout error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42113

0

55036

PDU SiS interface failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42114

0

55037

Spacecraft SpaceWire interface error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42118

0

55038

DPU Time anomaly  (timecode inconsistent, not synchronized).Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42126

0

55039

DPU Timecode anomaly  (timecode missing, invalid).If less than 5 events are received in a reporting in a day, then no action
Else:
Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42127

0

55040

A software reset has been requested by TC.Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

3

1207

42302

0

55041

DPU AHB uncorrectable error (memory corruption detected by EDAC)Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42306

0

55042

EEPROM failure (write, timeout).Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42307

0

55043

DPU memory load operation fails.Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

3

1207

42314

0

55044

PDU SiS interface failure (read / write invalid address).Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42315

0

55045

Spacecraft SpaceWire interface error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42319

0

55046

Boot Error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42331

0

55047

DBS buffer overflow.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42351

0

55048

Missing or corrupted configuration parameter block.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42511

0

55049

Permanent ADC failure (too many errors have occurred.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42503

0

55051

PDU link fatal error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42509

0

55052

Unexpected DPU reset.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42115

0

55100

LFR SpaceWire low severity error detected.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42116

0

55101

TDS SpaceWire low severity error detected.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42117

0

55102

THR SpaceWire low severity error detected.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42122

0

55103

LFR RMAP error (general error code, invalid key, early EOP...).Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42123

0

55104

TDS RMAP error (general error code, invalid key, early EOP...).Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42124

0

55105

THR RMAP error (general error code, invalid key, early EOP...).Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42125

0

55106

RPW current consumption warning.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42112

0

55107

BIA SiS interface failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42106

0

55108

BIA link timeout error.Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42137

0

55109

Error during compression process.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

2

1207

42109

0

55110

LFR link error.Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42110

0

55111

TDS link error.Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

2

1207

42111

0

55112

THR link error.Log as UNEXPECTED in the daily report for engineer. Engineer to inform PI per email!

5

3

1207

42316

0

55113

LFR SpaceWire medium severity error detected.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42317

0

55114

TDS SpaceWire medium severity error detected.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42318

0

55115

THR SpaceWire medium severity error detected.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42323

0

55116

LFR permanent error (too many RMAP errors).Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42324

0

55117

TDS permanent error (too many RMAP errors).Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42325

0

55118

THR permanent error (too many RMAP errors).Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42329

0

55120

RPW current consumption alarm.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42320

0

55121

LFR Boot Error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42321

0

55122

TDS Boot Error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42322

0

55123

THR Boot Error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42313

0

55124

BIA SiS interface failure (read / write invalid address).Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42337

0

55125

DAS buffer overflow.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42344

0

55126

Communication error with LFR.The generation of this event is expected upon execution of TCs from Remarks section. In this case, log as "expected due to ddddd" in the daily report. Otherwise call engineer (during working hours)

5

3

1207

42346

0

55127

Communication error with TDS.The generation of this event is expected upon execution of TCs from Remarks section. In this case, log as "expected due to ddddd" in the daily report. Otherwise call engineer (during working hours)

5

3

1207

42348

0

55128

Communication error with THR.The generation of this event is expected upon execution of TCs from Remarks section. In this case, log as "expected due to ddddd" in the daily report. Otherwise call engineer (during working hours)

5

3

1207

42326

0

55129

LFR command execution failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42327

0

55130

TDS command execution failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42328

0

55131

THR command execution failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42332

0

55132

DPU mode transition failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42333

0

55133

LFR mode transition failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42334

0

55134

TDS mode transition failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42335

0

55135

THR mode transition failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42352

0

55136

PDU operation failure (switch on failed, switch off failed).Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42508

0

55137

RPW temperature critical alarm.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42502

0

55139

BIA link fatal error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42504

0

55140

LFR link fatal error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42505

0

55141

TDS link fatal error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42506

0

55142

THR link fatal error.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42353

0

55429

Too many time anomalies have consecutively occurred.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42336

0

55434

Service 20 packet no more received.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42515

0

55436

BIAS high voltage failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42516

0

55437

Overcurrent on RPW equipment.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42354

0

55443

BIAS sweeping failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42355

0

55450

BIAS calibration failure.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

3

1207

42356

0

55451

A delayed mode transition has been aborted.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!

5

4

1207

42517

0

55472

Over-voltage detected.Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report. Engineer to call PI during working hours!!


Commands:

We have 139 RPW commands. Each one of them have the same action in case it fails execution ---> "Call Engineer asap (during working hours) and log as UNEXPECTED in the daily report"