Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The instrument is set in the SBM_DETECTION SCIENCE submode with the "Low rate" configuration.

The "StateMode" section gives the general state software mode of the sub-system (i.e., S/W mode). The "configuration" section gives the detailed configuration of the sub-system. The "Associated sequences" section gives the list of TC sequences to apply to set the instrument in this state. The "Attributes" section lists the TC and/or formal parameters values for this state.

...

DPU is started with DAS in SCIENCE SBM_DETECTION submode.

Configuration

TBW

Asssociated sequences

TBW

Attributes

TC packetDescriptionDefault value

TC_DPU_ENABLE_COMPRESSION / TC_DPU_DISABLE_COMPRESSION

Waveform packet compression activation/deactivationN/A

...

THR is started in SCIENCE SURVEY_NORMAL submode.

Configuration

This configuration is the default configuration, or "Direction-Finding" config. The measurement time is 12 seconds.

TBW

Asssociated sequences

TBWImage Removed


Attributes

TC packet / TC parametersDescriptionDefault value




...

LFR is started in SCIENCE SURVEY_NORMAL mode.

Configuration

TBW

Asssociated sequences

TBWImage Removed


Attributes

TC packet / TC parametersDescriptionDefault value




...

TDS is started in SCIENCE SURVEY_NORMAL mode.

Configuration

Image Removed

1D histo:

  • Xaxis: LOG_HIST_64
  • Yaxis: PEAK_W_AMP, RMS_W_AMP, RMS_S_AMP, MAXAMP_CH1 

2D histo:

  • Xaxis: LOG_HIST_128
  • Yaxis: HISTA_32
  • Zaxis: DA_VS_RE

TBW

Asssociated sequences

TBW


Attributes

TC packet / TC parametersDescriptionDefault value




...

Bias unit is ON

Configuration

TBW

Asssociated sequences

TBW

Attributes

SCM setting

SCM is ON

...

Telemetry

  • With compression: 4.584 TBD kbps
  • Without compression: 6.7454 TBD kbps

Power consumption

  • Hot case: 17.7W
  • Cold case: 19.1W