Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


This page gives information about the RPW Flight Procedures (RFP).


About the RPW Flight Procedures

According to the FOP preparation plan, the flight procedures are divided into three categories: the Flight Control Procedures (FCP), the Contingency Recovery Procedures (CRP) and the Commissioning Procedures (COM).

The RPW procedures files are archived in the /Procedures folder of the https://gitlab.obspm.fr/ROC/OpsLib gitlab repository (restricted access). A test version of this repository is available in https://gitlab.obspm.fr/ROC/OpsLib-Test (restricted access).

For each of these categories, a table is given with the following columns:

  • Name – Name of the procedure (according to the ESA convention)
  • Description - Short description of the procedure (to be reported into the info sheet of the Excel export)
  • State Instrument mode at start (i.e., initial ROP)State at end (i.e., final ROP)
  • Instrument mode at intermediate step (optional)
  • Instrument mode at end
  • Author(s) – Entity that creates the procedure
  • Total duration – Total duration of the procedure in seconds (including the minimal time delay to be let after the last TC execution)
  • Minimal time delay at the end - Minimal time delay in seconds to be let at the end of the procedure execution (i.e., to be let after the last TC execution)
  • Status – Status of the procedure writing (i.e., "Done", "In Progress", "To Be Done", "Validated", "To Be replaced")

The possible RPW instrument modes are listed here.

Editing a procedure

The SOC provides to the instrument teams an online "Procedure Builder" than can be used to create/edit procedures. The site dedicated to RPW is available here. Nevertheless, the SOC cannot guarantee that this tool will be maintained during the whole mission, and the instrument teams are invited to develop and maintain their own tool. In the case of the ROC, the FIGARO tool, accessible via the MUSIC Web portal will replace at medium term the SOC procedure builder.

The procedures are delivered as MOIS import format files, which are formatted 97-2003 Excel files (see the FOP procedure input ICD for more details).

The naming convention can be found in the FOP preparation plan.

Warning
titleIMPORTANT

Please visit the operation guidelines page before editing a procedure!


Flight Control Procedures (FCP)

The table below gives the list of generic procedures, other than specific to the contingency recovery or commissioning operations (see next sections).


Switch OFF the RPW prime power interface via OBCP.
Total duration
NameDescriptionState Mode at startIntermediate mode (if any)Mode State at endAuthor(s)(s)StatusComments

IW-FCP-001

RPW switch ON in SAFE mode using the prime/A interface for LCL and SpaceWireRPW_OFF


Go from SCIENCE/BACKUP mode to SAFE mode properly, then switch OFF the RPW prime power interface via OBCP.

RPW_SCIENCE

RPW_BACKUP


RPW_OFFRPW_SAFE_PRIME-ADone
IW-FCP-002RPW switch ON in SAFE mode using the prime/B interface for LCL and SpaceWireRPW_OFFGo from SCIENCE/BACKUP mode to SAFE mode properly, then switch OFF the RPW redundant power interface via OBCP.

RPW_SCIENCE

RPW_BACKUP

RPW_OFF

RPW_SAFE_PRIME-B

Done
IW-FCP-010Transition to SERVICE mode (from standby to equipments onBoot RPW DBS in prime power interface (UNIT_A)RPW_SERVICEOFF
RPW_SERVICESAFE (prime)Done
IW-FCP-011Start DAS from EEPROM1 and transition to STANDBY modeBoot RPW DBS in redundant power interface (UNIT_B)RPW_SAFEOFF
RPW_STANDBYSAFE (prime B)Done
IW-FCP-030Boot RPW DAS from EEPROM1RPW_SAFE
RPW_STANDBY

IW-FCP-031Enter SERVICE mode and switch on RPW equipmentRPW_STANDBY
RPW_SERVICE (with all equipement ON)

IW-FCP-032Enter SERVICE modeRPW_STANDBY
RPW_SERVICE (with all equipment OFF)

IW-FCP-033Switch the converter (CONV)RPW_SERVICE
RPW_SERVICEstart IW_FCP-019 after 5 sec



IW-FCP-012034BOOT LFR from EEPROM1 + Disabled Verif BootRPW_SERVICE
RPW_SERVICEDone
IW-FCP-013035BOOT THR from EEPROM1 + Disabled Verif BootRPW_SERVICE
RPW_SERVICEDone
IW-FCP-014036BOOT TDS from EEPROM1 + Disabled Verif BootRPW_SERVICE
RPW_SERVICEDone

IW-FCP-015037

Switch ON BIASRPW_SERVICE
RPW_SERVICEDone
IW-FCP-016038PA Switch ONRPW_SERVICE
RPW_SERVICEDone
IW-FCP-017Switch on converterRPW_SAFERPW_SERVICEDoneIW-FCP-018039SCM switch ONRPW_SERVICE
RPW_SERVICEDone
IW-FCP-019Transition to SERVICE mode (from standby to equipments off)RPW_STANDBYRPW_SERVICEDone040IW-FCP-030Configure TDS, LFR and THR for the RPW_SCIENCE mode with the NORMAL-NORMAL_DEFAULT config.RPW_SERVICE
RPW_SERVICEDone
IW-FCP-001 to be renamed to IW-FCP-009IW-FCP-031041Configure the Bias for the RPW_SCIENCE with the NORMAL-NORMAL_DEFAULT config.RPW_SERVICE
RPW_SERVICEDone
IW-FCP-002 to be renamed to IW-FCP-009IW-FCP-032042Enter in RPW_SCIENCE -NORMAL_DEFAULTmodeRPW_SERVICE
RPW_SCIENCE-NORMAL_DEFAULTDone

IW-FCP-

003 to be renamed to IW-FCP-009

IW-FCP-033043

Configure and execute the BIAS sweepRPW_SCIENCE
RPW_SCIENCE2501

Done
IW-FCP-034044 Internal Calibration for LFRRPW_SCIENCE
RPW_SCIENCEDone
IW-FCP-045BIAS CalibrationRPW_SCIENCE
RPW_SCIENCE600

Done
















IW-FCP-035Enter in RPW mode safeRPW_SCIENCE
RPW_SAFEDone
IW-FCP-036BIAS CalibrationRPW_SCIENCE
RPW_SCIENCE380

Done
IW-FCP-037Enter in RPW_SURVEY-BURST_DEFAULTRPW_SCIENCE
RPW_SCIENCE-BURST_DEFAULTDone
IW-FCP-038Configure TDS, LFR and THR for the RPW_SCIENCE-BURST_DEFAULT configRPW_SERVICE
RPW_SERVICEDone
IW-FCP-039Configure DPU and DAS + configure HK periodRPW_SAFE
RPW_SERVICEDone
IW-FCP-040LOAD TDS, LFR common parametersRPW_SERVICE
RPW_SERVICEDone
IW-FCP-041Configure TDS, LFR for sbm1 modeRPW_SERVICE
RPW_SERVICEDone
IW-FCP-042Configure TDS, LFR for sbm2 modeRPW_SERVICE
RPW_SERVICEDone
IW-FCP-043Configure TDS LFM parametersRPW_SERVICE
RPW_SERVICEDone
IW-FCP-044 Configure internal Calibration for THRRPW_SERVICE
RPW_SERVICEDone
IW-FCP-045

DUMP configurations and clear all the counters and statistic information in the DAS HK reports

RPW_SERVICE
RPW_SERVICEDone
IW-FCP-046Enter in RPW_SURVEY-BACKUP (through RPW Service mode)RPW_SCIENCE
RPW_SCIENCE-BACKUPDone
IW-FCP-027xxEnter in RPW_SURVEY-BURST_TDS_single_endedRPW_SCIENCE
To be done
IW-FCP-028xxEnter in RPW_SURVEY-BURST_TDS_dipoleRPW_SCIENCE
RPW_SCIENCETo be done
IW-FCP-030xxFix the current value on BIAS 1,2,3RPW_SCIENCE
RPW_SCIENCEDone
IW-FCP-XXXEnter in RPW STANDBY modeRPW_SAFE
RPW_STANDBY
To be done
IW-FCP-XXXEnter in RPW SAFE modeRPW_STANDBY
RPW_SAFE
To be done
IW-FCP-XXXEnter in RPW SERVICE mode from the RPW SCIENCE modeRPW_SCIENCE
RPW_SERVICE
To be done

Contingency Recovery Procedures (CRP)

The table below gives the list of procedures specific to the contingency recovery operations.

NameDescriptionConfiguration at startConfiguration at endAuthor(s)Creation dateStatusComments








Commissioning Procedures (COM)

The table below gives the list of procedures specific to the commissionning operations, including ANT and iBoom deployments, as well as the interference campaign.

NameDescriptionConfiguration at startConfiguration at endAuthor(s)Creation dateStatusComments









Action Items

Action items relative to the flight procedures

#DescriptionAssigneeCommentIssueDone
1IW-FCP-021: TNR-HFR must be set in specific mag. config during the LFR calibration, in order to check B measurements

  •   
2Identify formal parameters for each procedure

  •   
3Check that expected TM are provided in procedures (e.g., Ack., dump, etc.)

  •   
4Merge procedures that can be run with formal parameters (e.g., EEPROM1/EEPROM2/RAM loading, PRIME-A/PRIME-B, etc.)

  •   
5

Complete the document of Sylvain Lodiot about the instrument state model (see document "rpw.docx" attached below). Especially see for the power (for STANDBY mode, need to split)



  •   

Attached Items

  • rpw.docx (Sylvain Lodiot inital RPW state model – see Philippe Plasson's mail on (16:36).