This page gives information about the RPW Flight Procedures (RFP).
About the RPW Flight Procedures
According to the FOP preparation plan, the flight procedures are divided into three categories: the Flight Control Procedures (FCP), the Contingency Recovery Procedures (CRP) and the Commissioning Procedures (COM).
The RPW procedures files are archived in the /Procedures folder of the https://gitlab.obspm.fr/ROC/OpsLib gitlab repository (restricted access). A test version of this repository is available in https://gitlab.obspm.fr/ROC/OpsLib-Test (restricted access).
For each of these categories, a table is given below with the following columns:
- Procedure name – Name of the procedure (according to the ESA convention)
- Sequence name - Name of the sequence in the procedure
- Description - Short description of the sequence
- Instrument state at start of the sequence
- Instrument state at end of the sequence
- Author(s) – Entity that creates the procedure
- Status – Status of the procedure (i.e., "Written", "In Progress", "To Be Written", "Tested", "Submitted", "Accepted", "Rejected", "To Be Updated")
- Comments – any relevant comment
The possible RPW instrument modes are listed here.
Building/Editing a procedure
The procedure/sequence naming convention can be found in the FOP preparation plan. Especially, be sure to follow the procedure number range definition.
Warning | ||
---|---|---|
| ||
The RPW procedures were initialy delivered to MOC as MOIS import Excel format files, which are formatted 97-2003 Excel files with specific sheets and columns (see the FOP procedure input ICD for more details). In this format, there must be only one sequence per procedure file. Nevertheless, after discussions with the MOC, it has been decided to work with several sequences per procedure. In this new scheme, an input Excel file does not correspond anymore to a procedure but to a sequence. Moreover the Excel file naming convention is now "sequenceName.xlsx". Please visit the operation guidelines page before editing a procedure! |
Flight Control Procedures (FCP)
The table below gives the list of generic procedures, other than specific to the contingency recovery or commissioning operations (see next sections).
Procedure Name | Sequence name | Theme | Description | Mode at start | Mode at end | Author(s) | Status | Comments | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IW-FCP-001 | AIWF001A | Nominal switch OFF via OBCP | From SAFE mode switch OFF the RPW power interface (UNIT_A and UNIT_B ) via OBCP. | RPW_SAFE | RPW_OFF | Written | TC for turning off RPW is given in the SSS (see SSS-OB-030) TM checks added (to be verified) | |||||||||||||
IW-FCP-002 | AIWF002A | Other OFF procedures | From SAFE mode switch OFF the RPW power interface (UNIT_A and UNIT_B ) via manual. | RPW_SAFE | RPW_OFF | Written | TM checks added (to be verified) | |||||||||||||
IW-FCP-010 | AIWF010A | Nominal switch ON via OBCP | Boot RPW DBS in prime power interface (UNIT_A) via OBCP | RPW_OFF | RPW_SAFE | Written | ||||||||||||||
IW-FCP-011 | AIWF011A | Nominal switch ON via manual | Boot RPW DBS prime power interface (UNIT_A) via manual | RPW_OFF | RPW_SAFE | Written | ||||||||||||||
IW-FCP-030 | AIWF030A | Modes transition (i.e., boot DAS and transition from SAFE to STANDBY mode) | Boot RPW DAS from EEPROM1 (default), EEPROM2, RAM | RPW_SAFE | RPW_STANDBY | Written | ||||||||||||||
IW-FCP-031 | AIWF031A | Nominal Switch On equipment | Enter SERVICE mode and switch on all RPW equipment units | RPW_STANDBY | RPW_SERVICE (with all equipement ON) | Written | ||||||||||||||
IW-FCP- | 043AIWF043A | Enter SERVICE Mode | Enter SERVICE mode032 | AIWF032A | Configuration DPU and DAS | configure HK period | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | Duration of the procedure about 10s. This procedure is not used in nominal case to come from STANDBY mode (enter SERVICE from STANDBY mode without switching-on all equipment) | ||||||||||
IW-FCP- | 042032 | AIWF042A | Switch On equipment | Switch the converter (CONV)AIWF032B | Configuration DPU and DAS | Load DPU and DAS common parameters | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | |||||||||||
IW-FCP- | 042032 | AIWF042B | Switch On equipment | BOOT LFR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootAIWF032C | Configuration DPU and DAS | Load DPU and DAS power parameters | RPW_SERVICE RPW_ | SERVICEUnknown User (deconchy), SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | ||||||||||
IW-FCP- | 042032 | AIWF042C | Switch On equipment | BOOT THR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootAIWF032D | Configuration DPU and DAS | Configure Bias High Voltage parameter | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE | Unknown User (deconchy), RPW_SCIENCE RPW_BACKUP | Written | ||||||||||
IW-FCP- | 042032 | AIWF042D | Switch On equipment | BOOT TDS from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootAIWF032E | Configuration DPU and DAS | Configure parameters for monitoring temperature | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE | Unknown User (deconchy), RPW_SCIENCE RPW_BACKUP | Written | ||||||||||
IW-FCP- | 042032 | AIWF042E | Switch On equipment | Switch ON BIASAIWF032F | Configuration DPU and DAS | Configure Waveform parameters | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE | Unknown User (deconchy), RPW_SCIENCE RPW_BACKUP | Written | ||||||||||
IW-FCP- | 042032 | AIWF042F | Switch On equipment | PA Switch ONAIWF032G | Configuration DPU and DAS | Configure SBM1 parameters | RPW_SERVICE RPW_ | SERVICEWritten | IW-FCP-042 | AIWF042G | Switch On equipment | SCM switch ON | RPW_SERVICE | RPW_SERVICE | Unknown User (deconchy),SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | |||
IW-FCP- | 037032 | AIWF037AAIWF032H | Configuration | THRDPU and DAS | Configure | THR for the RPW SCIENCE SURVEY_NORMAL mode.SBM2 parameters | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_ | SERVICEUnknown User (deconchy), BACKUP | Written | The default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config. | |||||||||
IW-FCP- | 040032 | AIWF040AAIWF032I | Configuration | BiasConfigure the Bias (mode, and relay) for the RPW SCIENCE mode.DPU and DAS | Configure SC potential computation algorithm | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_ | SERVICEUnknown User (deconchy), BACKUP | Written | The default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config. | IW-FCP-035 | AIWF035A | Modes transition SCIENCE | Enter in SCIENCE SURVEY_NORMAL submode|||||||
IW-FCP-032 | AIWF032J | Configuration DPU and DAS | Clear HK counter | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_ | SCIENCEUnknown User (deconchy), BACKUP | Written | |||||||||||||
IW-FCP- | 033032 | AIWF033DAIWF032K | Configuration | BiasConfigure and execute the BIAS sweepDPU and DAS | Enable HK parameter report generation | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE | Unknown User (deconchy), RPW_BACKUP | Written | |||||||||||
IW-FCP- | 033032 | AIWF033A | Calibration | Internal Calibration for LFRAIWF032L | Configuration DPU and DAS | Dump DAS parameters | RPW_ | SCIENCESERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | ||||||||||
IW-FCP-033 | AIWF033A | Calibration | Internal Calibration for LFR | RPW_SCIENCE | RPW_SCIENCE | Written | TNR- | Written | TNR-HFR must be set in specific mag. config during the LFR calibration, in order to check B measurements | |||||||||||
IW-FCP-033 | AIWF033B | Calibration | BIAS Calibration | RPW_SCIENCE | RPW_SCIENCE | Written | ||||||||||||||
IW-FCP- | 035033 | AIWF035BAIWF033C | Modes transition SCIENCE | Enter in SCIENCE SURVEY_BURST submodeCalibration | Run THR internal calibration | RPW_SCIENCE RPW_ | SCIENCEUnknown User (deconchy), Antonio VecchioBACKUP | RPW_SCIENCE RPW_BACKUP | Written | |||||||||||
IW-FCP-037033 | AIWF037BAIWF033D | Configuration THRBias | Configure THR for the RPW SCIENCE SURVEY_BURST mode. and execute the BIAS sweep | RPW_SCIENCE | RPW_SCIENCE | Written | The default value for TC formal parameters shall correspond to the BURST-DEFAULT config. | |||||||||||||
IW-FCP- | 032034 | AIWF032A | Configuration DPU and DAS | configure HK periodAIWF034A | Dump | Dump LFR, TDS, THR parameters | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | |||||||||||
IW-FCP- | 032034 | AIWF032B | Configuration DPU and DAS | Load DPU and DAS common parametersAIWF034B | Dump | Dump TDS Triggered snapshots | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Antonio VecchioWritten | |||||||||||
IW-FCP- | 032035 | AIWF032C | Configuration DPU and DAS | Load DPU and DAS power parametersAIWF035A | Modes transition SCIENCE | Enter in SCIENCE SURVEY_NORMAL submode | RPW_SERVICE RPW_SCIENCE | RPW_ | BACKUPSCIENCE | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | |||||||||
IW-FCP- | 032035 | AIWF032D | Configuration DPU and DAS | Configure Bias High Voltage parameter | RPW_SERVICEAIWF035B | Modes transition SCIENCE | Enter in SCIENCE SURVEY_BURST submode | RPW_SCIENCE | RPW_ | BACKUPSCIENCE | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | ||||||||
IW-FCP- | 032035 | AIWF032E | Configuration DPU and DAS | Configure parameters for monitoring temperatureAIWF035C | Modes transition SCIENCE | Enter in SBM_DETECTION mode | RPW_SERVICE RPW_SCIENCE | RPW_ | BACKUPSBM_ | SERVICEDETECTION | Written | |||||||||
IW-FCP- | 032036 | AIWF032FAIWF036A | Configuration | DPU and DASConfigure Waveform parametersBias Current | Configuration Bias currents | RPW_SERVICE RPW_SCIENCE | RPW_ | BACKUPSERVICE RPW_SCIENCE | RPW_BACKUPWritten | |||||||||||
IW-FCP- | 032037 | AIWF032GAIWF037A | Configuration | DPU and DASTHR | Configure | SBM1 parametersTHR for the RPW SCIENCE SURVEY_NORMAL mode. | RPW_ | BACKUPSERVICE | RPW_SERVICE | Written | The default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config. | |||||||||
IW-FCP- | 032037 | AIWF032HAIWF037B | Configuration | DPU and DASTHR | Configure | SBM2 parametersRPW_SERVICETHR for the RPW SCIENCE SURVEY_BURST mode. | RPW_SCIENCE | RPW_SCIENCE | Written | The default value for TC formal parameters shall correspond to the BURST-DEFAULT config. | ||||||||||
RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | IW-FCP- | 032037 | AIWF032IAIWF037C | Configuration | DPU and DASConfigure SC potential computation algorithmTHR | Load calibration parameters for THR | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | ||||||||||
IW-FCP- | 032038 | AIWF032JAIWF038A | Configuration | DPU and DASClear HK counterTDS | Load common parameters of TDS | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | ||||||||||||
IW-FCP- | 032038 | AIWF032KAIWF038B | Configuration | DPU and DASEnable HK parameter report generationTDS | Configuration of TDS for SBM1 mode | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | The default value for TC formal parameters shall correspond to the SBM1-DEFAULT config. | |||||||||||
IW-FCP- | 032038 | AIWF032LAIWF038C | Configuration | DPU and DASTDS | Configuration of TDS for SBM2 mode | Dump DAS parametersRPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Diane BérardWritten | IW-FCP-038 | The default value for TC formal parameters shall correspond to the SBM2-DEFAULT config. | ||||||||||
IW-FCP-038 | AIWF038D | AIWF038AConfiguration TDS | Load common parameters of TDSConfigure TDS LFM parameters | RPW_SERVICE | RPW_SCIENCERPW_ | BACKUPRPW_SERVICE | Written | The default value for TC formal parameters shall correspond to the LFM-DEFAULT config. | ||||||||||||
IW-FCP-038 | AIWF038BAIWF038E | Configuration TDS | Configuration ofConfigure TDS for | SBM1 modethe RPW SCIENCE SURVEY_NORMAL mode. | RPW_SERVICE | RPW_ | SCIENCESERVICE | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | The default value for TC formal parameters shall correspond to the | SBM1NORMAL-DEFAULT config. | |||||||||
IW-FCP-038 | AIWF038F | Configuration TDS | Configure TDS for the RPW SCIENCE SURVEY_BURST mode. | RPW_SERVICE RPW_SCIENCE | RPW_SERVICE RPW_SCIENCE | Written | ||||||||||||||
IW-FCP-039 | AIWF039A | Configuration LFR | Configuration of LFR for SBM1 mode | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | The default value for TC formal parameters shall correspond to the SBM1-DEFAULT config. | |||||||||||||
IW-FCP- | 038039 | AIWF038CAIWF039B | Configuration TDSLFR | Configuration of TDS LFR for SBM2 mode | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | The default value for TC formal parameters shall correspond to the SBM2-DEFAULT config. | ||||||||||||
IW-FCP-039 | AIWF039BAIWF039C | Configuration LFR | Load common parameters of LFR | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-039 | AIWF039D | Configuration LFR | Configure LFR for the RPW SCIENCE SURVEY_NORMAL mode. Configuration of LFR for SBM2 mode | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | The default value for TC formal parameters shall correspond to the SBM2NORMAL-DEFAULT config. | |||||||||||||
IW-FCP- | 038039 | AIWF038DAIWF039E | Configuration | TDSLFR | Configure | TDS LFM parametersLFR for the RPW SCIENCE SURVEY_BURST mode. | RPW_SERVICE RPW_ | SERVICEWritten | The default value for TC formal parameters shall correspond to the LFM-DEFAULT config. | IW-FCP-037 | AIWF037C | Configuration THR | Load calibration parameters for THR | SCIENCE RPW_BACKUP | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | ||||
IW-FCP- | 034040 | AIWF034AAIWF040A | Dump | Dump LFR, TDS, THR parameters | Configuration Bias | Configure the Bias (mode, and relay) for the RPW SCIENCE mode. | RPW_SERVICE | RPW_BACKUPRPW_SERVICE | Written | The default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config. | ||||||||||
IW-FCP- | 034041 | AIWF034BAIWF041A | Dump | Dump TDS Triggered snapshotsCompression | Enable the compression of the waveform products. | RPW_SERVICE | RPW_ | SCIENCESERVICE | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | ||||||||||
IW-FCP- | 044041 | AIWF044AAIWF041B | Enter BACKUP Mode | Enter in SCIENCE SURVEY_BACKUP submodeCompression | Disable the compression of the waveform products. | RPW_SERVICE | RPW_ | BACKUPSERVICE | Written | |||||||||||
IW-FCP- | 039042 | AIWF039C | Configuration LFR | Load common parameters of LFRAIWF042A | Switch On equipment | Switch on the converter (CONV) | RPW_SERVICE | RPW_SERVICE | Written | |||||||||||
IW-FCP- | 045042 | AIWF045A | Enter STANDBY Mode | Enter in RPW STANDBY mode from any other mode (except SAFE and OFF)AIWF042B | Switch On equipment | BOOT LFR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif Boot | RPW_SERVICE | RPW_ | SCIENCESERVICE | RPW_STANDBY | Written | If required, equipment units are automatically switched-off by the DPU before entering in the STANDBY mode. | ||||||||
IW-FCP- | 035042 | AIWF035C | Modes transition SCIENCE | Enter in SBM_DETECTION modeAIWF042C | Switch On equipment | BOOT THR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif Boot | RPW_SERVICE | RPW_ | SCIENCESERVICE | RPW_SBM_DETECTION | Written | |||||||||
IW-FCP- | 038042 | AIWF038E | Configuration TDS | Configure TDS for the RPW SCIENCE SURVEY_NORMAL mode.AIWF042D | Switch On equipment | BOOT TDS from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif Boot | RPW_SERVICE | RPW_SERVICE | Written | The default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.|||||||||||
IW-FCP- | 039042 | AIWF039D | Configuration LFR | Configure LFR for the RPW SCIENCE SURVEY_NORMAL mode.AIWF042E | Switch On equipment | Switch ON BIAS | RPW_SERVICE | RPW_SERVICE | Written | The default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.|||||||||||
IW-FCP- | 038042 | AIWF038F | Configuration TDS | Configure TDS for the RPW SCIENCE SURVEY_BURST mode.AIWF042F | Switch On equipment | PA Switch ON | RPW_SERVICE | RPW_SCIENCERPW_SERVICE | Written | |||||||||||
IW-FCP- | 039042 | AIWF039E | Configuration LFR | Configure LFR for the RPW SCIENCE SURVEY_BURST mode.AIWF042G | Switch On equipment | SCM switch ON | RPW_SERVICE | RPW_ | SCIENCESERVICE | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | |||||||||
IW-FCP- | 033043 | AIWF033CAIWF043A | Calibration | Enter SERVICE Mode | Enter SERVICE modeRun THR internal calibration | RPW_SCIENCE RPW_BACKUP | RPW_ | SCIENCEWritten | SERVICE | Written | Duration of the procedure about 10s. This procedure is not used in nominal case to come from STANDBY mode (enter SERVICE from STANDBY mode without switching-on all equipment) | |||||||||
IW-FCP- | 046044 | AIWF046AAIWF044A | Enter | SAFEBACKUP Mode | Go to SAFE mode (DBS) with TC_DPU_RESET commandEnter in SCIENCE SURVEY_BACKUP submode | RPW_ | STANDBYSERVICE | RPW_ | SERVICERPW_SAFE | Written | In principle, the TC_DPU_RESET can be also executed from the RPW_SCIENCE/BACKUP/SERVICE modes, but this brutal transition is not allowed in the nominal case. | BACKUP | Written | |||||||
IW-FCP-045 | AIWF045A | Enter STANDBY Mode | Enter in RPW STANDBY mode from any other mode (except SAFE and OFF) | RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_STANDBY | Written | If required, equipment units are automatically switched-off by the DPU before entering in the STANDBY mode. | |||||||||||||
IW-FCP-046 | AIWF046A | Enter SAFE Mode | Go to SAFE mode (DBS) with TC_DPU_RESET command | RPW_STANDBY RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SAFE | Written | In principle, the TC_DPU_RESET can be also executed from the RPW_SCIENCE/BACKUP/SERVICE modes, but this brutal transition is not allowed in the nominal case. | |||||||||||||
IW-FCP-047 | AIWF047A | Switch off equipment | Switch off HV | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047B | Switch off equipment | Switch off TDS | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047C | Switch off equipment | Switch off Bias PA | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047D | Switch off equipment | Switch off Bias | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047E | Switch off equipment | Switch off LFR | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047F | Switch off equipment | Switch off THR | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047G | Switch off equipment | Switch off SCM | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047H | Switch off equipment | Switch off ANT PA1 | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047I | Switch off equipment | Switch off ANT PA2 | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
IW-FCP-047 | AIWF047J | Switch off equipment | Switch off ANT PA3 | IW-FCP-036 | AIWF036A | Configuration Bias Current | Configuration Bias currents | RPW_SERVICE | RPW_SCIENCERPW_SERVICE RPW_SCIENCE | Written | ||||||||||
IW-FCP-041047 | AIWF041AAIWF047K | Compression | Enable the compression of the waveform products.Switch off equipment | Switch off CONV | RPW_SERVICE | RPW_SERVICE | Antonio VecchioWritten | |||||||||||||
IW-FCP-041048 | AIWF041BAIWF048A | Compression | DBS configuration | Load common parameters for DBSDisable the compression of the waveform products. | RPW_SERVICESAFE | RPW_SERVICESAFE | Written | |||||||||||||
IW-FCP-260 | AIWF260A | Memory dump (S6) | Dump DPU memory (TC_DPU_DUMP_MEMORY - Service 6) | RPW_SAFE RPW_SERVICE RPW_SCIENCE RPW_BACKUP | RPW_SAFE RPW_SERVICE RPW_SCIENCE RPW_BACKUP | Written | ||||||||||||||
IW-FCP-261 | AIWF261A | Change the DAS number | Change the DAS number in HK when applied on the DAS 3.6.0.4 | RPW_SERVICE | RPW_SERVICE | Written | ||||||||||||||
Dump THR memory (TC_THR_DUMP_MEMORY - Service 6) | All modes except RPW_STANDBY | All modes except RPW_STANDBY | To be written | |||||||||||||||||
Dump LFR memory (TC_LFR_DUMP_MEMORY - Service 6) | All modes except RPW_STANDBY | All modes except RPW_STANDBY | To be written | |||||||||||||||||
Dump TDS memory (TC_TDS_DUMP_MEMORY - Service 6) | All modes except RPW_STANDBY | All modes except RPW_STANDBY | To be written | |||||||||||||||||
IW-FCP-370 | AIWF370A | "ping" (PUS, Service 17) | Run a test connection (PUS, Service 17) with the TC_DPU_TEST_CONNECTION {ZIW00012} (i.e. "ping") | RPW_SAFE RPW_STANDBY RPW_SERVICE | RPW_SAFE RPW_STANDBY RPW_SERVICE | Written |
Contingency Recovery Procedures (CRP)
The table below gives the list of procedures specific to the contingency recovery operations.
Name | Description | Mode at start | Mode at end | Author(s) | Status | Comments |
---|---|---|---|---|---|---|
IW-CRP-001 | Emergency Switch OFF | All | RPW_OFF | To be written | ||
IW-CRP-010 | Contingency ON procedures (UNIT A) | RPW_OFF | RPW_SAFE | To be written | ||
IW-CRP-011 | Contingency ON procedures (UNIT B) | RPW_OFF | RPW_SAFE | To be written | ||
IW-CRP-020 | Go in SAFE mode | RPW_SCIENCE | RPW_SAFE | Written | ||
IW-CRP-021 | Phase back to Default Mode (i.e. to resume science after contingency) | To be written | ||||
IW-CRP-XXX | Enter SERVICE mode from SAFE mode | RPW_SAFE | RPW_SERVICE | To be written | ||
IW-CRP-XXX | Enter SERVICE mode from OFF mode | RPW_OFF | RPW_SERVICE | To be written | ||
IW-CRP-XXX | Enter STANDBY mode | RPW_SAFE | RPW_STANDBY | To be written | ||
IW-CRP-XXX | Enter SERVICE Mode | RPW_STANDBY | RPW_SERVICE | To be written | ||
IW-CRP-XXX | Enter SCIENCE_NORMAL | RPW_SERVICE | RPW_SCIENCE | To be written | ||
Commissioning Procedures (COM)
The table below gives the list of procedures specific to the commissionning operations, including ANT and iBoom deployments, as well as the interference campaign.
Name | Description | Mode at start | Mode at end | Author(s) | Status | Comments |
---|---|---|---|---|---|---|
IW-COM-XXX | Configure TDS with specific "single_ended" SURVEY_BURST mode configuration for the interference campaign. | RPW_SCIENCE | RPW_SCIENCE | To be written | ||
IW-COM-XXX | Configure TDS with specific "dipole" SURVEY_BURST mode configuration for the interference campaign. | RPW_SCIENCE | RPW_SCIENCE | To be written | ||
IW-COM-XXX | Configure THR with specific config. for interference campaign | To be written | ||||
IW-COM-XXX | Configure LFR with specific config. for interference campaign (9 configs) | To be written | ||||
IW-COM-XXX | Configure TDS with specific config. for iBoom deployment | To be written | ||||
IW-COM-XXX | Configure LFR with specific config. for iBoom deployment | To be written | ||||
IW-COM-XXX | Configure THR with specific config. for iBoom deployment | To be written | ||||
IW-COM-XXX | Configure LFR with specific config. for ANT deployment | To be written | ||||
IW-COM-XXX | Configure THR with specific config. for ANT deployment | To be written | ||||
IW-COM-XXX | Configure TDS with specific config. for ANT deployment | To be written | ||||
IW-COM-XXX | Send 22V to fire the frangibolt | To be written | ||||
IW-COM-XXX | ANT calibration | To be written | ||||
IW-COM-XXX | Configure LFR with specific config. for First Switch on | To be written | ||||
IW-COM-XXX | Configure THR with specific config. for First Switch on | To be written | ||||
IW-COM-XXX | Configure TDS with specific config. for First Switch on | To be written |
Open issues
Issues | Comment | Status |
---|---|---|
Compression activation/deactivation shall be added when configuring the sub-systems in SERVICE mode in some way | Might be a single procedure for this task | Fixed |
Need a procedure to enter in SBM_DETECTION | Done with IW-FCP-058 | Fixed |
Does the formal parameter (FP) mechanism should be used for COM and CRP? | Yes we can use FP (S. Lodiot confirmation) | Fixed |
Need a procedure to enter in SERVICE mode from SCIENCE | Done with IW-FCP-032 | Fixed |
Do IW-FCP-001 and IW-FCP-002 can only contain the TC to switch-off the instrument? | Fixed | |
Does IW-CRP-020 can be used nominally to enter in mode SAFE? | The IW-FCP-064 can be used too | Fixed |
Action Items
See JIRA ROC-OPERATIONS project board.
Attached Items
- rpw.docx (Sylvain Lodiot inital RPW state model – see Philippe Plasson's mail on (16:36).