This page gives information about the RPW Flight Procedures (RFP).


About the RPW Flight Procedures

According to the FOP preparation plan, the flight procedures are divided into three categories: the Flight Control Procedures (FCP), the Contingency Recovery Procedures (CRP) and the Commissioning Procedures (COM).

The RPW procedures files are archived in the /Procedures folder of the https://gitlab.obspm.fr/ROC/OpsLib gitlab repository (restricted access). A test version of this repository is available in https://gitlab.obspm.fr/ROC/OpsLib-Test (restricted access).

For each of these categories, a table is given below with the following columns:

  • Procedure name – Name of the procedure (according to the ESA convention)
  • Sequence name - Name of the sequence in the procedure
  • Description - Short description of the sequence
  • Instrument state at start of the sequence
  • Instrument state at end of the sequence
  • Author(s) – Entity that creates the procedure
  • Status – Status of the procedure (i.e., "Written", "In Progress", "To Be Written", "Tested", "Submitted", "Accepted", "Rejected", "To Be Updated")
  • Comments – any relevant comment

The possible RPW instrument modes are listed here.

Building/Editing a procedure

The procedure/sequence naming convention can be found in the FOP preparation plan. Especially, be sure to follow the procedure number range definition.

Warning
titleIMPORTANT

The RPW procedures were initialy delivered to MOC as MOIS import Excel format files, which are formatted 97-2003 Excel files with specific sheets and columns (see the FOP procedure input ICD for more details). In this format, there must be only one sequence per procedure file.

Nevertheless, after discussions with the MOC, it has been decided to work with several sequences per procedure. In this new scheme, an input Excel file does not correspond anymore to a procedure but to a sequence. Moreover the Excel file naming convention is now "sequenceName.xlsx".

Please visit the operation guidelines page before editing a procedure!


Flight Control Procedures (FCP)

The table below gives the list of generic procedures, other than specific to the contingency recovery or commissioning operations (see next sections).

043Enter SERVICE mode042Switch the converter (CONV)042BOOT LFR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootSERVICEUnknown User (deconchy)042BOOT THR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootUnknown User (deconchy), 042BOOT TDS from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootUnknown User (deconchy), 042Switch ON BIASUnknown User (deconchy), 042PA Switch ONSERVICEUnknown User (deconchy), 037AIWF037A THR THR for the RPW SCIENCE SURVEY_NORMAL mode.SERVICEUnknown User (deconchy), IW040AIWF040A BiasConfigure the Bias (mode, and relay) for the RPW SCIENCE mode.SERVICEUnknown User (deconchy), Enter in SCIENCE SURVEY_NORMAL submodeSCIENCEUnknown User (deconchy), 033AIWF033D BiasConfigure and execute the BIAS sweepUnknown User (deconchy), 033Internal Calibration for LFRSCIENCETNR-035AIWF035BEnter in SCIENCE SURVEY_BURST submodeSCIENCEUnknown User (deconchy), Antonio Vecchio032configure HK period032Load DPU and DAS common parametersAntonio Vecchio032Load DPU and DAS power parametersBACKUP
032RPW_SERVICEBACKUP
032Configure parameters for monitoring temperatureBACKUP
RPWSERVICE

RPW_SCIENCE

RPW_BACKUP

032AIWF032F DPU and DASConfigure Waveform parametersBACKUP
RPW_RPW_BACKUP032AIWF032G DPU and DAS SBM1 parameters

RPW_SERVICE

RPW_SCIENCEBACKUP

RPW_SCIENCE

RPW_BACKUP

032AIWF032H DPU and DAS SBM2 parametersRPW_SERVICEBACKUP
032AIWF032I DPU and DASConfigure SC potential computation algorithm032AIWF032J DPU and DASClear HK counter032AIWF032K DPU and DASEnable HK parameter report generation032AIWF032L DPU and DASDump DAS parametersDiane BérardAIWF038ALoad common parameters of TDSRPW_SCIENCEBACKUPRPW_

RPW_SCIENCE

RPW_BACKUP

AIWF038BConfiguration of SBM1 modeSCIENCE

RPW_BACKUP

SBM1038AIWF039B038AIWF038D TDS TDS LFM parametersSERVICE

RPW_SERVICE

RPW_034AIWF034A

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SCIENCE

RPW_BACKUP

034AIWF034BDump TDS Triggered snapshotsSCIENCE

RPW_BACKUP

044AIWF044AEnter in SCIENCE SURVEY_BACKUP submodeBACKUP039Load common parameters of LFR045Enter in RPW STANDBY mode from any other mode (except SAFE and OFF)SCIENCE

RPW_BACKUP

035Enter in SBM_DETECTION modeSCIENCE038Configure TDS for the RPW SCIENCE SURVEY_NORMAL mode. The default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.039Configure LFR for the RPW SCIENCE SURVEY_NORMAL mode. 

RPW_SCIENCE

RPW_BACKUP

RPW_SCIENCE

RPW_BACKUP

The default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.038Configure TDS for the RPW SCIENCE SURVEY_BURST mode.RPW_SCIENCE

RPW_SCIENCE

039Configure LFR for the RPW SCIENCE SURVEY_BURST mode.SCIENCE

RPW_BACKUP

033AIWF033CSCIENCE

RPW_BACKUP

Written046AIWF046A SAFE Go to SAFE mode (DBS) with TC_DPU_RESET commandSTANDBYSERVICE

RPW_SCIENCE

RPW_BACKUP

AIWF041AEnable the compression of the waveform products.Antonio Vecchio
Procedure NameSequence nameThemeDescriptionMode at startMode at endAuthor(s)StatusComments
IW-FCP-001AIWF001ANominal switch OFF via OBCP

From SAFE mode switch OFF the RPW power interface (UNIT_A and UNIT_B ) via OBCP.

RPW_SAFE

RPW_OFFWritten

TC for turning off RPW is given in the SSS (see SSS-OB-030)

TM checks added (to be verified)

IW-FCP-002AIWF002AOther OFF proceduresFrom SAFE mode switch OFF the RPW power interface (UNIT_A and UNIT_B ) via manual.

RPW_SAFE

RPW_OFF

Written

TM checks added (to be verified)

IW-FCP-010AIWF010ANominal switch ON via OBCPBoot RPW DBS in prime power interface (UNIT_A) via OBCPRPW_OFFRPW_SAFE
Written
IW-FCP-011AIWF011ANominal switch ON via manualBoot RPW DBS prime power interface (UNIT_A) via manualRPW_OFFRPW_SAFE
Written
IW-FCP-030AIWF030AModes transition (i.e., boot DAS and transition from SAFE to STANDBY mode)Boot RPW DAS from EEPROM1 (default), EEPROM2, RAMRPW_SAFERPW_STANDBYWritten
IW-FCP-031AIWF031ANominal Switch On equipmentEnter SERVICE mode and switch on all RPW equipment unitsRPW_STANDBYRPW_SERVICE (with all equipement ON)Written
IW-FCP-AIWF043AEnter SERVICE Mode032AIWF032AConfiguration DPU and DASconfigure HK period

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written

Duration of the procedure about 10s.

This procedure is not used in nominal case to come from STANDBY mode (enter SERVICE from STANDBY mode without switching-on all equipment)


IW-FCP-032AIWF042ASwitch On equipmentAIWF032BConfiguration DPU and DASLoad DPU and DAS common parameters

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-032AIWF042BSwitch On equipmentAIWF032CConfiguration DPU and DASLoad DPU and DAS power parameters

RPW_SERVICE

RPW_

SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-032AIWF042CSwitch On equipmentAIWF032DConfiguration DPU and DASConfigure Bias High Voltage parameter

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-032AIWF042DSwitch On equipmentAIWF032EConfiguration DPU and DASConfigure parameters for monitoring temperature

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-032AIWF042ESwitch On equipmentAIWF032FConfiguration DPU and DASConfigure Waveform parameters

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-032AIWF042FSwitch On equipmentAIWF032GConfiguration DPU and DASConfigure SBM1 parameters

RPW_SERVICE

RPW_

WrittenIW-FCP-042AIWF042GSwitch On equipmentSCM switch ONRPW_SERVICERPW_SERVICE

SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-032AIWF032HConfiguration DPU and DASConfigure SBM2 parameters

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_

BACKUP

WrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.
IW-FCP-032AIWF032IConfiguration DPU and DASConfigure SC potential computation algorithm

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_

BACKUP

WrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.IW-FCP-035AIWF035AModes transition SCIENCE
IW-FCP-032AIWF032JConfiguration DPU and DASClear HK counter

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_

BACKUP

Written
IW-FCP-032AIWF032KConfiguration DPU and DASEnable HK parameter report generation

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-032AIWF033ACalibrationAIWF032LConfiguration DPU and DASDump DAS parameters

RPW_

SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-033AIWF033ACalibrationInternal Calibration for LFRRPW_SCIENCERPW_SCIENCEWrittenTNR-WrittenHFR must be set in specific mag. config during the LFR calibration, in order to check B measurements
IW-FCP-033AIWF033BCalibrationBIAS CalibrationRPW_SCIENCERPW_SCIENCEWritten
IW-FCP-033AIWF033CModes transition SCIENCECalibrationRun THR internal calibration

RPW_SCIENCE

RPW_

BACKUP

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-037033AIWF037BAIWF033DConfiguration THRBiasConfigure THR for the RPW SCIENCE SURVEY_BURST mode. and execute the BIAS sweepRPW_SCIENCERPW_SCIENCEWrittenThe default value for TC formal parameters shall correspond to the BURST-DEFAULT config.
IW-FCP-034AIWF032AConfiguration DPU and DASAIWF034ADumpDump LFR, TDS, THR parameters

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-034AIWF032BConfiguration DPU and DASAIWF034BDumpDump TDS Triggered snapshots

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-035AIWF032CConfiguration DPU and DASAIWF035AModes transition SCIENCEEnter in SCIENCE SURVEY_NORMAL submode

RPW_SERVICE

RPW_SCIENCE

RPW_SCIENCE

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-035AIWF032DConfiguration DPU and DASConfigure Bias High Voltage parameterAIWF035BModes transition SCIENCEEnter in SCIENCE SURVEY_BURST submodeRPW_SCIENCERPW_SCIENCE

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-035AIWF032EConfiguration DPU and DASAIWF035CModes transition SCIENCEEnter in SBM_DETECTION mode

RPW_SERVICE

RPW_SCIENCE

RPW_SBM_DETECTIONWritten
IW-FCP-036AIWF036AConfiguration Bias CurrentConfiguration Bias currents

RPW_SERVICE

RPW_SCIENCE

RPW_

SERVICE

RPW_SCIENCE

Written
IW-FCP-037AIWF037AConfiguration THRConfigure THR for the RPW SCIENCE SURVEY_NORMAL mode.RPW_SERVICERPW_SERVICEWrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.
IW-FCP-037AIWF037BConfiguration THRConfigure THR for the RPW SCIENCE SURVEY_BURST mode. RPW_SCIENCERPW_SCIENCEWrittenThe default value for TC formal parameters shall correspond to the BURST-DEFAULT config.

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenIW-FCP-037AIWF037CConfiguration THRLoad calibration parameters for THR

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-038AIWF038AConfiguration TDSLoad common parameters of TDS

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-038AIWF038BConfiguration TDSConfiguration of TDS for SBM1 mode

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenThe default value for TC formal parameters shall correspond to the SBM1-DEFAULT config.
IW-FCP-038AIWF038CConfiguration TDSConfiguration of TDS for SBM2 mode

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenIW-FCP-038The default value for TC formal parameters shall correspond to the SBM2-DEFAULT config.
IW-FCP-038AIWF038DConfiguration TDS

Configure TDS LFM parameters

RPW_SERVICERPW_SERVICEWrittenThe default value for TC formal parameters shall correspond to the LFM-DEFAULT config.
IW-FCP-038AIWF038EConfiguration TDSConfigure TDS for the RPW SCIENCE SURVEY_NORMAL mode. RPW_SERVICERPW_SERVICE

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.
IW-FCP-038AIWF038FConfiguration TDS

Configure TDS for the RPW SCIENCE SURVEY_BURST mode.

RPW_SERVICE

RPW_SCIENCE

RPW_SERVICE

RPW_SCIENCE

Written
IW-FCP-039AIWF039AConfiguration LFRConfiguration of LFR for SBM1 mode

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenThe default value for TC formal parameters shall correspond to the SBM1-DEFAULT config.
IW-FCP-039AIWF038CAIWF039BConfiguration TDSLFRConfiguration of TDS LFR for SBM2 mode

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenThe default value for TC formal parameters shall correspond to the SBM2-DEFAULT config.
IW-FCP-039AIWF039CConfiguration LFRLoad common parameters of LFR

RPW_SERVICE

RPW_SERVICE

Written
IW-FCP-039AIWF039DConfiguration LFRConfigure LFR for the RPW SCIENCE SURVEY_NORMAL mode. Configuration of LFR for SBM2 mode

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenThe default value for TC formal parameters shall correspond to the SBM2NORMAL-DEFAULT config.
IW-FCP-039AIWF039EConfiguration LFR

Configure

LFR for the RPW SCIENCE SURVEY_BURST mode.

RPW_SERVICE

RPW_

WrittenThe default value for TC formal parameters shall correspond to the LFM-DEFAULT config.IW-FCP-037AIWF037CConfiguration THRLoad calibration parameters for THR

SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-040AIWF040ADumpDump LFR, TDS, THR parametersConfiguration BiasConfigure the Bias (mode, and relay) for the RPW SCIENCE mode.RPW_SERVICERPW_SERVICEWrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.
IW-FCP-041AIWF041ADumpCompressionEnable the compression of the waveform products.

RPW_SERVICE

RPW_

SERVICE

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-041AIWF041BEnter BACKUP ModeCompressionDisable the compression of the waveform products.

RPW_SERVICE

RPW_

SERVICE

Written
IW-FCP-042AIWF039CConfiguration LFRAIWF042ASwitch On equipmentSwitch on the converter (CONV)RPW_SERVICERPW_SERVICEWritten
IW-FCP-042AIWF045AEnter STANDBY ModeAIWF042BSwitch On equipmentBOOT LFR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootRPW_SERVICERPW_SERVICERPW_STANDBYWrittenIf required, equipment units are automatically switched-off by the DPU before entering in the STANDBY mode.
IW-FCP-042AIWF035CModes transition SCIENCEAIWF042CSwitch On equipmentBOOT THR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootRPW_SERVICERPW_SERVICERPW_SBM_DETECTIONWritten
IW-FCP-042AIWF038EConfiguration TDSAIWF042DSwitch On equipmentBOOT TDS from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootRPW_SERVICERPW_SERVICEWritten
IW-FCP-042AIWF039DConfiguration LFRAIWF042ESwitch On equipmentSwitch ON BIASRPW_SERVICERPW_SERVICEWritten
IW-FCP-042AIWF038FConfiguration TDSAIWF042FSwitch On equipmentPA Switch ONRPW_SERVICERPW_SERVICEWritten
IW-FCP-042AIWF039EConfiguration LFRAIWF042GSwitch On equipmentSCM switch ONRPW_SERVICERPW_SERVICE

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-043AIWF043ACalibrationEnter SERVICE ModeEnter SERVICE modeRun THR internal calibration

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICEWritten

Duration of the procedure about 10s.

This procedure is not used in nominal case to come from STANDBY mode (enter SERVICE from STANDBY mode without switching-on all equipment)

IW-FCP-044AIWF044AEnter BACKUP ModeEnter in SCIENCE SURVEY_BACKUP submodeRPW_SERVICERPW_RPW_SAFEWrittenIn principle, the TC_DPU_RESET can be also executed from the RPW_SCIENCE/BACKUP/SERVICE modes, but this brutal transition is not allowed in the nominal case.BACKUPWritten
IW-FCP-045AIWF045AEnter STANDBY ModeEnter in RPW STANDBY mode from any other mode (except SAFE and OFF)

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_STANDBYWrittenIf required, equipment units are automatically switched-off by the DPU before entering in the STANDBY mode.
IW-FCP-046AIWF046AEnter SAFE ModeGo to SAFE mode (DBS) with TC_DPU_RESET command

RPW_STANDBY

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SAFEWrittenIn principle, the TC_DPU_RESET can be also executed from the RPW_SCIENCE/BACKUP/SERVICE modes, but this brutal transition is not allowed in the nominal case.
IW-FCP-047AIWF047ASwitch off equipmentSwitch off HVRPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047BSwitch off equipmentSwitch off TDSRPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047CSwitch off equipmentSwitch off Bias PARPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047DSwitch off equipmentSwitch off BiasRPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047ESwitch off equipmentSwitch off LFRRPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047FSwitch off equipmentSwitch off THRRPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047GSwitch off equipmentSwitch off SCMRPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047HSwitch off equipmentSwitch off ANT PA1RPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047ISwitch off equipmentSwitch off ANT PA2RPW_SERVICERPW_SERVICEWritten
IW-FCP-047AIWF047JSwitch off equipmentSwitch off ANT PA3IW-FCP-036AIWF036AConfiguration Bias CurrentConfiguration Bias currentsRPW_SERVICERPW_SCIENCERPW_SERVICE

RPW_SCIENCE

Written
IW-FCP-041047AIWF047KCompressionSwitch off equipmentSwitch off CONVRPW_SERVICERPW_SERVICEWritten
IW-FCP-041048AIWF041BAIWF048ACompressionDBS configurationLoad common parameters for DBSDisable the compression of the waveform products.RPW_SERVICESAFERPW_SERVICESAFEWritten




















































































































































































IW-FCP-260AIWF260AMemory dump (S6)Dump DPU memory (TC_DPU_DUMP_MEMORY - Service 6)

RPW_SAFE

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SAFE

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-261AIWF261AChange the DAS number

Change the DAS number in HK when applied on the DAS  3.6.0.4

RPW_SERVICE

RPW_SERVICE

Written



Dump THR memory (TC_THR_DUMP_MEMORY - Service 6)All modes except RPW_STANDBYAll modes except RPW_STANDBY
To be written



Dump LFR memory (TC_LFR_DUMP_MEMORY - Service 6)All modes except RPW_STANDBYAll modes except RPW_STANDBY
To be written



Dump TDS memory (TC_TDS_DUMP_MEMORY - Service 6)All modes except RPW_STANDBYAll modes except RPW_STANDBY
To be written
IW-FCP-370AIWF370A"ping" (PUS, Service 17)Run a test connection (PUS, Service 17) with the TC_DPU_TEST_CONNECTION {ZIW00012} (i.e. "ping")

RPW_SAFE

RPW_STANDBY

RPW_SERVICE

RPW_SAFE

RPW_STANDBY

RPW_SERVICE

Written

Contingency Recovery Procedures (CRP)

The table below gives the list of procedures specific to the contingency recovery operations.

NameDescriptionMode at startMode at endAuthor(s)StatusComments
IW-CRP-001Emergency Switch OFFAllRPW_OFF
To be written
IW-CRP-010Contingency ON procedures (UNIT A)RPW_OFFRPW_SAFE
To be written
IW-CRP-011Contingency ON procedures (UNIT B)RPW_OFFRPW_SAFE
To be written
IW-CRP-020Go in SAFE modeRPW_SCIENCERPW_SAFEWritten
IW-CRP-021

Phase back to Default Mode (i.e. to resume science after contingency)




To be written
IW-CRP-XXX

Enter SERVICE mode from SAFE mode


RPW_SAFERPW_SERVICE
To be written
IW-CRP-XXX

Enter SERVICE mode from OFF mode


RPW_OFFRPW_SERVICE
To be written
IW-CRP-XXXEnter STANDBY modeRPW_SAFERPW_STANDBY
To be written
IW-CRP-XXXEnter SERVICE ModeRPW_STANDBYRPW_SERVICE
To be written
IW-CRP-XXXEnter SCIENCE_NORMALRPW_SERVICERPW_SCIENCE
To be written







Commissioning Procedures (COM)

The table below gives the list of procedures specific to the commissionning operations, including ANT and iBoom deployments, as well as the interference campaign.

NameDescriptionMode at startMode at endAuthor(s)StatusComments
IW-COM-XXXConfigure TDS with specific "single_ended" SURVEY_BURST mode configuration for the interference campaign.RPW_SCIENCE

RPW_SCIENCE


To be written
IW-COM-XXXConfigure TDS with specific "dipole" SURVEY_BURST mode configuration for the interference campaign.RPW_SCIENCERPW_SCIENCE


To be written
IW-COM-XXXConfigure THR with specific config. for interference campaign


To be written
IW-COM-XXXConfigure LFR with specific config. for interference campaign (9 configs)


To be written
IW-COM-XXXConfigure TDS with specific config. for iBoom deployment


To be written
IW-COM-XXXConfigure LFR with specific config. for iBoom deployment


To be written
IW-COM-XXXConfigure THR with specific config. for iBoom deployment


To be written
IW-COM-XXXConfigure LFR with specific config. for ANT deployment


To be written
IW-COM-XXXConfigure THR with specific config. for ANT deployment


To be written
IW-COM-XXXConfigure TDS with specific config. for ANT deployment


To be written
IW-COM-XXXSend 22V to fire the frangibolt


To be written
IW-COM-XXXANT calibration


To be written
IW-COM-XXXConfigure LFR with specific config. for First Switch on


To be written
IW-COM-XXXConfigure THR with specific config. for First Switch on


To be written
IW-COM-XXXConfigure TDS with specific config. for First Switch on


To be written

Open issues

IssuesCommentStatus
Compression activation/deactivation shall be added when configuring the sub-systems in SERVICE mode in some wayMight be a single procedure for this taskFixed
Need a procedure to enter in SBM_DETECTIONDone with IW-FCP-058Fixed
Does the formal parameter (FP) mechanism should be used for COM and CRP?Yes we can use FP (S. Lodiot confirmation)Fixed
Need a procedure to enter in SERVICE mode from SCIENCEDone with IW-FCP-032Fixed
Do IW-FCP-001 and IW-FCP-002 can only contain the TC to switch-off the instrument?
Fixed
Does IW-CRP-020 can be used nominally to enter in mode SAFE?The IW-FCP-064 can be used tooFixed

Action Items

See JIRA ROC-OPERATIONS project board.

Attached Items

  • rpw.docx (Sylvain Lodiot inital RPW state model – see Philippe Plasson's mail on (16:36).