Context

IGST 4_2 are tests run at MOC (ESA Darmstadt) on May 15th 2018, in order to test sequences of:

  • Switch-on,
  • Ping,
  • exercise the different modes and changes between them (test the state model in the ORCD),
  • dump with S6 of one of the instrument memories,
  • Switch-off.

The datapack which contains the procedure, sequences and the timeline of the plan is given in RPW IGST page.

Tests have ben run by :

  • S. Lodiot (MOC)
  • D. Bérard (ROC)
  • A. Vecchio (ROC)

Test environnement

IGST 4_2 tests have been run on MEB EM2 with IDB 4.3.3.

Sequences used during the tests were send to MOC weeks before and were available for IGST test.

A slot of two hours were dedicated to RPW tests, during which each sequence was send manually. Between two sequences, TM parameters were checked manually.


For information, here is the document that details the actions run during IGST 4_2 for every instrument.

Results

Table below gives the timeline of the tests, and corresponding comments.


Sequence numberPurposeOK/NOKComments
AIWF011AOFF→ SAFENOKMore time has to be left before time synchronisation
AIWF370APingOK
AIWF030ASAFE → STANDBYOK
AIWF031ASTANDBY → SERVICEOK
AIWF032AConfigure HK periodOK
AIWF032BLoad DPU and DAS common parametersOK
AIWF032CLoad DPU and DAS power parametersOK
AIWF032EConfigure parameters for monitoring temperatureOK
AIWF032FConfigure Waveform parametersOK
AIWF032GConfigure SBM1 parametersOK
AIWF032HConfigure SBM2 parametersOK
AIWF032IConfigure SC potential computation algorithmOK
AIWF032JClear HK counterOK
AIWF032KEnable HK parameter report generationOK
AIWF037AConfig THR for NormalOK
AIWF037BConfig THR for BurstOK
AIWF037CConfig THR calibration parametersNOK

This TC was not executed whatever the moment during the test. The error seems to be in the structure of the TC itself.

Key Summary T Created Updated Due Assignee Reporter P Status Resolution
Loading...
Refresh

AIWF038AConfig TDS common paramOK


AIWF038EConfig TDS for NormalOK
AIWF038BConfig TDS for SBM1OK
AIWF038CConfig TDS for SBM2OK
AIWF038DConfig TDS LFMOK
AIWF038FConfig TDS for BurstOK
AIWF039AConfig LFR for SBM1OK
AIWF039BConfig LFR for SBM2OK
AIWF039CConfig LFR common paramOK
AIWF039DConfig LFR for NormalOK
AIWF039EConfig LFR for BurstOK
AIFW034ADump TDS,LFR,THR parametersOK
AIWF035ASERVICE → SCIENCE NORMALOK
AIWF035BSCIENCE NORMAL → SCIENCE BURSTOK
AIWF035CSCIENCE BURST → SBM DETECTIONOK
AIWF043ASBM DETECTION → SERVICEOK
AIWF035CSERVICE SBM DETECTIONOK
AIWF035BSBM DETECTIONSCIENCE BURSTOK
AIWF035ASCIENCE BURST→ SCIENCE NORMALOK
AIWF035CSCIENCE NORMALSBM DETECTIONOK
AIWF035ASBM DETECTION→ SCIENCE NORMALOK
AIWF043ASCIENCE NORMAL→ SERVICEOK
AIWF044ASERVICE → SCIENCE BACK UPOK
AIWF043ASCIENCE BACK UP→ SERVICEOK
AIWF045ASERVICE → STANDBYOK
AIWF043ASTANDBY→ SERVICEOK
AIWF042ASwitch on the converter (CONV)OK
AIWF042BBOOT LFR OK
AIWF042CBoot THROK
AIWF042DBoot TDSOK
AIWF042ESwitch ON BIASOK
AIWF037AConfig THR for NormalOK
AIWF037BConfig THR for BurstOK
AIWF037CConfig THR calibration parametersNOK

This TC was not executed whatever the moment during the test. The error seems to be in the structure of the TC itself.

Key Summary T Created Updated Due Assignee Reporter P Status Resolution
Loading...
Refresh

AIWF038AConfig TDS common paramOK
AIWF038EConfig TDS for NormalOK
AIWF038BConfig TDS for SBM1OK
AIWF038CConfig TDS for SBM2OK
AIWF038DConfig TDS LFMOK
AIWF038FConfig TDS for BurstOK
AIWF039AConfig LFR for SBM1OK
AIWF039BConfig LFR for SBM2OK
AIWF039CConfig LFR common paramOK
AIWF039DConfig LFR for NormalOK
AIWF039EConfig LFR for BurstOK
AIFW034ADump TDS,LFR,THR parametersOK
 AIWF035ASERVICE → SCIENCE NORMALOK
AIWF045ASCIENCE NORMAL → STANDBYOK
AIWF031ASTANDBY → SERVICEOK
AIWF037AConfig THR for NormalOK
AIWF037BConfig THR for BurstOK
AIWF037CConfig THR calibration parametersNOK

This TC was not executed whatever the moment during the test. The error seems to be in the structure of the TC itself.

Key Summary T Created Updated Due Assignee Reporter P Status Resolution
Loading...
Refresh

AIWF038AConfig TDS common paramOK
AIWF038EConfig TDS for NormalOK
AIWF038BConfig TDS for SBM1OK
AIWF038CConfig TDS for SBM2OK
AIWF038DConfig TDS LFMOK
AIWF038FConfig TDS for BurstOK
AIWF039AConfig LFR for SBM1OK
AIWF039BConfig LFR for SBM2OK
AIWF039CConfig LFR common paramOK
AIWF039DConfig LFR for NormalOK
AIWF039EConfig LFR for BurstOK
AIFW034ADump TDS,LFR,THR parametersOK
AIWF044ASERVICE → SCIENCE BACK UPOK
AIWF045ASCIENCE BACK UP → STANDBYOK
AIWF031ASTANDBY→ SERVICEOK
AIWF037AConfig THR for NormalOK
AIWF037BConfig THR for BurstOK
AIWF037CConfig THR calibration parametersNOK

This TC was not executed whatever the moment during the test. The error seems to be in the structure of the TC itself.

Key Summary T Created Updated Due Assignee Reporter P Status Resolution
Loading...
Refresh

AIWF038AConfig TDS common paramOK
AIWF038EConfig TDS for NormalOK
AIWF038BConfig TDS for SBM1OK
AIWF038CConfig TDS for SBM2OK
AIWF038DConfig TDS LFMOK
AIWF038FConfig TDS for BurstOK
AIWF039AConfig LFR for SBM1OK
AIWF039BConfig LFR for SBM2OK
AIWF039CConfig LFR common paramOK
AIWF039DConfig LFR for NormalOK
AIWF039EConfig LFR for BurstOK
AIFW034ADump TDS,LFR,THR parametersOK
AIWF035CSERVICE → SBM DETECTIONOK
AIWF045ASBM DETECTION → STANDBYOK
AIWF031ASTANDBY→ SERVICEOK
AIWF037AConfig THR for NormalOK
AIWF037BConfig THR for BurstOK
AIWF037CConfig THR calibration parametersNOK

This TC was not executed whatever the moment during the test. The error seems to be in the structure of the TC itself.

Key Summary T Created Updated Due Assignee Reporter P Status Resolution
Loading...
Refresh

AIWF038AConfig TDS common paramOK
AIWF038EConfig TDS for NormalOK
AIWF038BConfig TDS for SBM1OK
AIWF038CConfig TDS for SBM2OK
AIWF038DConfig TDS LFMOK
AIWF038FConfig TDS for BurstOK
AIWF039AConfig LFR for SBM1OK
AIWF039BConfig LFR for SBM2OK
AIWF039CConfig LFR common paramOK
AIWF039DConfig LFR for NormalOK
AIWF039EConfig LFR for BurstOK
AIFW034ADump TDS,LFR,THR parametersOK
AIWF035ASERVICE → SCIENCE NORMALOK
AIWF035BSCIENCE NORMAL → SCIENCE BURSTOK
AIWF045ASCIENCE BURST → STANDBYOK
AIWF043ASTANDBY→ SERVICEOK
AIWF261APatch MEMORYOK
AIWF260ADump memoryOK
AIWF046ASERVICE→ SAFEOK
AIWF001ASAFE → OFFOK


Test results

Test report

Report from MOC and related data are availaible in SOL-176_AR_attachments.zip

Test anomalies

Thus the only problem is with the loading of calibration parameters for TNR-HFR.  ROC team will investigate it.

See ROCOPE-171 - Getting issue details... STATUS

  • No labels