You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 105 Next »


This page gives information about the RPW Flight Procedures (RFP).


About the RPW Flight Procedures

According to the FOP preparation plan, the flight procedures are divided into three categories: the Flight Control Procedures (FCP), the Contingency Recovery Procedures (CRP) and the Commissioning Procedures (COM).

The RPW procedures files are archived in the /Procedures folder of the https://gitlab.obspm.fr/ROC/OpsLib gitlab repository (restricted access). A test version of this repository is available in https://gitlab.obspm.fr/ROC/OpsLib-Test (restricted access).

For each of these categories, a table is given with the following columns:

  • Name – Name of the procedure (according to the ESA convention)
  • Description - Short description of the procedure (to be reported into the info sheet of the Excel export)
  • Instrument mode at start
  • Instrument mode at end
  • Author(s) – Entity that creates the procedure
  • Total duration – Total duration of the procedure in seconds (including the minimal time delay to be let after the last TC execution)
  • Minimal time delay at the end - Minimal time delay in seconds to be let at the end of the procedure execution (i.e., to be let after the last TC execution)
  • Status – Status of the procedure (i.e., "Written", "In Progress", "To Be Written", "Tested", "Submitted", "Accepted", "Rejected", "To Be Updated")

The possible RPW instrument modes are listed here.

Editing a procedure

The SOC provides to the instrument teams an online "Procedure Builder" than can be used to create/edit procedures. The site dedicated to RPW is available here. Nevertheless, the SOC cannot guarantee that this tool will be maintained during the whole mission, and the instrument teams are invited to develop and maintain their own tool. In the case of the ROC, the FIGARO tool, accessible via the MUSIC Web portal will replace at medium term the SOC procedure builder.

The procedures are delivered as MOIS import format files, which are formatted 97-2003 Excel files (see the FOP procedure input ICD for more details).

The naming convention can be found in the FOP preparation plan.

IMPORTANT

Please visit the operation guidelines page before editing a procedure!


Flight Control Procedures (FCP)

The table below gives the list of generic procedures, other than specific to the contingency recovery or commissioning operations (see next sections).


Switch OFF the RPW prime power interface via OBCP.

NameDescriptionMode at startMode at endAuthor(s)StatusComments

IW-FCP-001


Go from SCIENCE/BACKUP mode to SAFE mode properly, then switch OFF the RPW prime power interface via OBCP.

RPW_SCIENCE

RPW_BACKUP

RPW_OFFWritten

Can we used only the TC_RPW_RESET TC to be able to go to SAFE from all modes?

TC for turning off RPW is given in the SSS (

see SSS-OB-030)

IW-FCP-002Go from SCIENCE/BACKUP mode to SAFE mode properly, then switch OFF the RPW redundant power interface via OBCP.

RPW_SCIENCE

RPW_BACKUP

RPW_OFF

Written

Can we used only the TC_RPW_RESET TC to be able to go to SAFE from all modes?

TC for turning off RPW is given in the SSS (

see SSS-OB-030)

IW-FCP-010Boot RPW DBS in prime power interface (UNIT_A)RPW_OFFRPW_SAFE (prime)Written
IW-FCP-011Boot RPW DBS in redundant power interface (UNIT_B)RPW_OFFRPW_SAFE (redundant)Written
IW-FCP-030Boot RPW DAS from EEPROM1RPW_SAFERPW_STANDBYWritten
IW-FCP-031Enter SERVICE mode and switch on RPW equipmentRPW_STANDBYRPW_SERVICE (with all equipement ON)Written
IW-FCP-032Enter SERVICE modeRPW_STANDBYRPW_SERVICE(with all equipment OFF)Written
IW-FCP-033Switch the converter (CONV)RPW_SERVICERPW_SERVICEWritten
IW-FCP-034BOOT LFR from EEPROM1 + Disabled Verif BootRPW_SERVICERPW_SERVICEWritten
IW-FCP-035BOOT THR from EEPROM1 + Disabled Verif BootRPW_SERVICERPW_SERVICEWritten
IW-FCP-036BOOT TDS from EEPROM1 + Disabled Verif BootRPW_SERVICERPW_SERVICEWritten

IW-FCP-037

Switch ON BIASRPW_SERVICERPW_SERVICEWritten
IW-FCP-038PA Switch ONRPW_SERVICERPW_SERVICEWritten
IW-FCP-039SCM switch ONRPW_SERVICERPW_SERVICEWritten
IW-FCP-040Configure TDS, LFR and THR for the RPW_SCIENCE mode with the NORMAL-DEFAULT config.RPW_SERVICERPW_SERVICEWritten
IW-FCP-041Configure the Bias (mode, relay and currents) for the RPW_SCIENCE with the NORMAL-DEFAULT config.RPW_SERVICERPW_SERVICEWritten
IW-FCP-042Enter in SCIENCE SURVEY_NORMAL submodeRPW_SERVICERPW_SCIENCEWritten

IW-FCP-043

Configure and execute the BIAS sweepRPW_SCIENCERPW_SCIENCEWritten
IW-FCP-044Internal Calibration for LFRRPW_SCIENCERPW_SCIENCEWrittenTNR-HFR must be set in specific mag. config during the LFR calibration, in order to check B measurements
IW-FCP-045BIAS CalibrationRPW_SCIENCERPW_SCIENCEWritten
IW-FCP-046Enter in SCIENCE SURVEY_BURST submodeRPW_SCIENCERPW_SCIENCEWritten
IW-FCP-047Configure TDS, LFR and THR for the RPW_SCIENCE mode with the BURST-DEFAULT config. RPW_SCIENCERPW_SCIENCEWritten
IW-FCP-048Configure DPU and DAS + configure HK period

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-049Load common parameters of LFR and TDS

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenSplit LFR and TDS parts?
IW-FCP-050Configuration of TDS, LFR for SBM1 mode

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-051Configuration of TDS, LFR for SBM2 mode

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-052

Configure TDS LFM parameters

RPW_SERVICERPW_SERVICEWritten
IW-FCP-053Load calibration parameters for THR

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

Written
IW-FCP-054Dump LFR, TDS, THR parameters and clear HK counters and statistic info

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

WrittenWhy HK clear at the end? (Separate procedure?)
IW-FCP-055Enter in SCIENCE SURVEY_BACKUP submodeRPW_SCIENCERPW_BACKUPWrittenMake stand-alone procedure for transition SERVICE to BACKUP?
IW-FCP-XXXEnter in RPW_SURVEY-BURST_TDS_single_endedRPW_SCIENCETo be written
IW-FCP-XXXEnter in RPW_SURVEY-BURST_TDS_dipoleRPW_SCIENCERPW_SCIENCETo be written
IW-FCP-XXXEnter in RPW STANDBY mode from SERVICE modeRPW_SERVICERPW_STANDBY
To be written
IW-FCP-XXXEnter in RPW SAFE modeRPW_STANDBYRPW_SAFE
To be written
IW-FCP-XXXEnter in RPW SERVICE mode from the RPW SCIENCE modeRPW_SCIENCERPW_SERVICE
To be written







Contingency Recovery Procedures (CRP)

The table below gives the list of procedures specific to the contingency recovery operations.

NameDescriptionConfiguration at startConfiguration at endAuthor(s)StatusComments
IW-CRP-020Go in SAFE modeRPW_SCIENCERPW_SAFEWrittenMight need to be only TC_DPU_RESET command (to be able to go fast in the SAFE mode from any other mode)

Commissioning Procedures (COM)

The table below gives the list of procedures specific to the commissionning operations, including ANT and iBoom deployments, as well as the interference campaign.

NameDescriptionConfiguration at startConfiguration at endAuthor(s)Creation dateStatusComments










Action Items

See JIRA ROC-OPERATIONS project board.

Open questions

Questionanswer(s)
How to deal with the compression?


Attached Items

  • rpw.docx (Sylvain Lodiot inital RPW state model – see Philippe Plasson's mail on (16:36).
  • No labels