This page gives information about the RPW Flight Procedures (RFP).
About the RPW Flight Procedures
According to the FOP preparation plan, the flight procedures are divided into three categories: the Flight Control Procedures (FCP), the Contingency Recovery Procedures (CRP) and the Commissioning Procedures (COM).
The RPW procedures files are archived in the /Procedures folder of the https://gitlab.obspm.fr/ROC/OpsLib gitlab repository (restricted access). A test version of this repository is available in https://gitlab.obspm.fr/ROC/OpsLib-Test (restricted access).
For each of these categories, a table is given with the following columns:
- Name – Name of the procedure (according to the ESA convention)
- Description - Short description of the procedure (to be reported into the info sheet of the Excel export)
- Instrument mode at start
- Instrument mode at end
- Author(s) – Entity that creates the procedure
- Total duration – Total duration of the procedure in seconds (including the minimal time delay to be let after the last TC execution)
- Minimal time delay at the end - Minimal time delay in seconds to be let at the end of the procedure execution (i.e., to be let after the last TC execution)
- Status – Status of the procedure (i.e., "Written", "In Progress", "To Be Written", "Tested", "Submitted", "Accepted", "Rejected", "To Be Updated")
The possible RPW instrument modes are listed here.
Editing a procedure
The SOC provides to the instrument teams an online "Procedure Builder" than can be used to create/edit procedures. The site dedicated to RPW is available here. Nevertheless, the SOC cannot guarantee that this tool will be maintained during the whole mission, and the instrument teams are invited to develop and maintain their own tool. In the case of the ROC, the FIGARO tool, accessible via the MUSIC Web portal will replace at medium term the SOC procedure builder.
The procedures are delivered as MOIS import format files, which are formatted 97-2003 Excel files (see the FOP procedure input ICD for more details).
The naming convention can be found in the FOP preparation plan.
IMPORTANT
Please visit the operation guidelines page before editing a procedure!
Flight Control Procedures (FCP)
The table below gives the list of generic procedures, other than specific to the contingency recovery or commissioning operations (see next sections).
Switch OFF the RPW prime power interface via OBCP.
Name | Description | Mode at start | Mode at end | Author(s) | Status | Comments |
---|---|---|---|---|---|---|
Go from SCIENCE/BACKUP mode to SAFE mode properly, then switch OFF the RPW prime power interface via OBCP. | RPW_SCIENCE RPW_BACKUP | RPW_OFF | Written | TC for turning off RPW is given in the SSS ( see SSS-OB-030)
| ||
IW-FCP-002 | Go from SCIENCE/BACKUP mode to SAFE mode properly, then switch OFF the RPW redundant power interface via OBCP. | RPW_SCIENCE RPW_BACKUP | RPW_OFF | Written | TC for turning off RPW is given in the SSS (see SSS-OB-030) | |
IW-FCP-010 | Boot RPW DBS in prime power interface (UNIT_A) | RPW_OFF | RPW_SAFE (prime) | Written | ||
IW-FCP-011 | Boot RPW DBS in redundant power interface (UNIT_B) | RPW_OFF | RPW_SAFE (redundant) | Written | ||
IW-FCP-030 | Boot RPW DAS from EEPROM1, EEPROM2, RAM | RPW_SAFE | RPW_STANDBY | Written | ||
IW-FCP-031 | Enter SERVICE mode and switch on RPW equipment | RPW_STANDBY | RPW_SERVICE (with all equipement ON) | Written | ||
IW-FCP-032 | Enter SERVICE mode | RPW_STANDBY RPW_BACKUP | RPW_SERVICE | Written | duration of the procedure about 10s. When coming from the STANDBY mode, all equipment are OFF. | |
IW-FCP-033 | Switch the converter (CONV) | RPW_SERVICE | RPW_SERVICE | Written | ||
IW-FCP-034 | BOOT LFR from EEPROM1, EEPROM2 and RAM + Disabled Verif Boot | RPW_SERVICE | RPW_SERVICE | Written | ||
IW-FCP-035 | BOOT THR from EEPROM1, EEPROM2 and RAM + Disabled Verif Boot | RPW_SERVICE | RPW_SERVICE | Written | ||
IW-FCP-036 | BOOT TDS from EEPROM1, EEPROM2 and RAM + Disabled Verif Boot | RPW_SERVICE | RPW_SERVICE | Written | ||
Switch ON BIAS | RPW_SERVICE | RPW_SERVICE | Written | |||
IW-FCP-038 | PA Switch ON | RPW_SERVICE | RPW_SERVICE | Written | ||
IW-FCP-039 | SCM switch ON | RPW_SERVICE | RPW_SERVICE | Written | ||
IW-FCP-040 | Configure THR for the RPW SCIENCE SURVEY_NORMAL mode. | RPW_SERVICE | RPW_SERVICE | Written | The default value for TC parameters shall correspond to the NORMAL-DEFAULT config. | |
IW-FCP-041 | Configure the Bias (mode, relay and currents) for the RPW SCIENCE mode. | RPW_SERVICE | RPW_SERVICE | Written | The default value for TC parameters shall correspond to the NORMAL-DEFAULT config. | |
IW-FCP-042 | Enter in SCIENCE SURVEY_NORMAL submode | RPW_SERVICE | RPW_SCIENCE | Written | ||
Configure and execute the BIAS sweep | RPW_SCIENCE | RPW_SCIENCE | Written | |||
IW-FCP-044 | Internal Calibration for LFR | RPW_SCIENCE | RPW_SCIENCE | Written | TNR-HFR must be set in specific mag. config during the LFR calibration, in order to check B measurements | |
IW-FCP-045 | BIAS Calibration | RPW_SCIENCE | RPW_SCIENCE | Written | ||
IW-FCP-046 | Enter in SCIENCE SURVEY_BURST submode | RPW_SCIENCE | RPW_SCIENCE | Written | ||
IW-FCP-047 | Configure TDS, LFR and THR for the RPW SCIENCE SURVEY_BURST mode. | RPW_SCIENCE | RPW_SCIENCE | Written | The default value for TC parameters shall correspond to the BURST-DEFAULT config. | |
IW-FCP-048 | Configure DPU and DAS + configure HK period | RPW_BACKUP | RPW_BACKUP | Written | ||
IW-FCP-049 | Load common parameters of TDS | RPW_BACKUP | RPW_BACKUP | Written | ||
IW-FCP-050 | Configuration of TDS, LFR for SBM1 mode | RPW_BACKUP | RPW_BACKUP | Written | The default value for TC parameters shall correspond to the SBM1-DEFAULT config. | |
IW-FCP-051 | Configuration of TDS, LFR for SBM2 mode | RPW_BACKUP | RPW_BACKUP | Written | The default value for TC parameters shall correspond to the SBM2-DEFAULT config. | |
IW-FCP-052 | Configure TDS LFM parameters | RPW_SERVICE | RPW_SERVICE | Written | The default value for TC parameters shall correspond to the LFM-DEFAULT config. | |
IW-FCP-053 | Load calibration parameters for THR | RPW_BACKUP | RPW_BACKUP | Written | ||
IW-FCP-054 | Dump LFR, TDS, THR parameters | RPW_BACKUP | RPW_BACKUP | Written | ||
IW-FCP-055 | Enter in SCIENCE SURVEY_BACKUP submode | RPW_SERVICE | RPW_BACKUP | Written | ||
IW-FCP-056 | Load common parameters of LFR | RPW_BACKUP | RPW_BACKUP | Written | ||
IW-FCP-057 | Enter in RPW STANDBY mode from SERVICE mode | RPW_SERVICE | RPW_STANDBY | Written | ||
IW-FCP-058 | Enter in SBM_DETECTION mode | RPW_SBM_DETECTION | Written | |||
IW-FCP-059 | Configure TDS for the RPW SCIENCE SURVEY_NORMAL mode. | RPW_SCIENCE | RPW_SCIENCE | Written | The default value for TC parameters shall correspond to the NORMAL-DEFAULT config. | |
IW-FCP-060 | Configure LFR for the RPW SCIENCE SURVEY_NORMAL mode. | RPW_SCIENCE | RPW_SCIENCE | Written | The default value for TC parameters shall correspond to the NORMAL-DEFAULT config. | |
IW-FCP-XXX | ||||||
IW-FCP-XXX | ||||||
IW-FCP-XXX | ||||||
IW-FCP-XXX | Run the THR internal calibration | RPW_BACKUP | RPW_BACKUP | To be written | ||
IW-FCP-XXX | Dump DPU memory (TC_DPU_DUMP_MEMORY - Service 6) | All modes except RPW_STAND_BY | All modes except RPW_STAND_BY | To be written | ||
IW-FCP-XXX | Dump THR memory (TC_THR_DUMP_MEMORY - Service 6) | All modes except RPW_STAND_BY | All modes except RPW_STAND_BY | To be written | ||
IW-FCP-XXX | Dump LFR memory (TC_LFR_DUMP_MEMORY - Service 6) | All modes except RPW_STAND_BY | All modes except RPW_STAND_BY | To be written | ||
IW-FCP-XXX | Dump TDS memory (TC_TDS_DUMP_MEMORY - Service 6) | All modes except RPW_STAND_BY | All modes except RPW_STAND_BY | To be written | ||
IW-FCP-XXX | Enter in RPW_SURVEY-BURST_TDS_single_ended | RPW_SCIENCE | To be written | |||
IW-FCP-XXX | Enter in RPW_SURVEY-BURST_TDS_dipole | RPW_SCIENCE | RPW_SCIENCE | To be written |
Contingency Recovery Procedures (CRP)
The table below gives the list of procedures specific to the contingency recovery operations.
Name | Description | Configuration at start | Configuration at end | Author(s) | Status | Comments |
---|---|---|---|---|---|---|
IW-CRP-020 | Go in SAFE mode | RPW_SCIENCE | RPW_SAFE | Written |
Commissioning Procedures (COM)
The table below gives the list of procedures specific to the commissionning operations, including ANT and iBoom deployments, as well as the interference campaign.
Name | Description | Configuration at start | Configuration at end | Author(s) | Creation date | Status | Comments |
---|---|---|---|---|---|---|---|
IW-COM-XXX |
Open issues
Issues | Comment |
---|---|
Compression activation/deactivation shall be added when configuring the sub-systems in SERVICE mode in some way | Might be a single procedure for this task |
Need a procedure to enter in SBM_DETECTION | |
Does the formal parameter (FP) mechanism can be used for COM and CRP? | |
Need a procedure to enter in SERVICE mode from SCIENCE | |
Do IW-FCP-001 and IW-FCP-002 can only contain the TC to switch-off the instrument? | |
Does IW-CRP-020 can be used nominally to enter in mode SAFE? |
Action Items
See JIRA ROC-OPERATIONS project board.
Attached Items
- rpw.docx (Sylvain Lodiot inital RPW state model – see Philippe Plasson's mail on (16:36).