This page gives information about the RPW Flight Procedures (RFP).


About the RPW Flight Procedures

According to the FOP preparation plan, the flight procedures are divided into three categories: the Flight Control Procedures (FCP), the Contingency Recovery Procedures (CRP) and the Commissioning Procedures (COM).

The RPW procedures files are archived in the /Procedures folder of the https://gitlab.obspm.fr/ROC/OpsLib gitlab repository (restricted access). A test version of this repository is available in https://gitlab.obspm.fr/ROC/OpsLib-Test (restricted access).

For each of these categories, a table is given with the following columns:

  • Name – Name of the procedure (according to the ESA convention)
  • Description - Short description of the procedure (to be reported into the info sheet of the Excel export)
  • Instrument mode at start
  • Instrument mode at end
  • Author(s) – Entity that creates the procedure
  • Status – Status of the procedure (i.e., "Written", "In Progress", "To Be Written", "Tested", "Submitted", "Accepted", "Rejected", "To Be Updated")
  • Comments – any relevant comment

The possible RPW instrument modes are listed here.

Editing a procedure

The SOC provides to the instrument teams an online "Procedure Builder" than can be used to create/edit procedures. The site dedicated to RPW is available here. Nevertheless, the SOC cannot guarantee that this tool will be maintained during the whole mission, and the instrument teams may develop and maintain their own tool (this particularly true when the teams want to write and/or test a procedure with upcoming version of the instrument IDB) . In the case of RPW, the FIGARO tool, accessible via the MUSIC Web portal will replace at medium term the SOC procedure builder.

The RPW procedures are delivered to MOC as MOIS import Excel format files, which are formatted 97-2003 Excel files with specific sheets and columns (see the FOP procedure input ICD for more details). In this format, there must be only one sequence per procedure file.

The procedure/sequence naming convention can be found in the FOP preparation plan.

IMPORTANT

Please visit the operation guidelines page before editing a procedure!

Flight Control Procedures (FCP)

The table below gives the list of generic procedures, other than specific to the contingency recovery or commissioning operations (see next sections).

NameDescriptionMode at startMode at endAuthor(s)StatusComments

IW-FCP-001


Go from SCIENCE/BACKUP mode to SAFE mode properly, then switch OFF the RPW prime power interface (UNIT_A) via OBCP.

RPW_SCIENCE

RPW_BACKUP

RPW_OFFWritten

TC for turning off RPW is given in the SSS (

see SSS-OB-030)

  • Verify with PP the possiility to use TC_DPU_RESET only
IW-FCP-002Go from SCIENCE/BACKUP mode to SAFE mode properly, then switch OFF the RPW redundant power interface (UNIT_B) via OBCP.

RPW_SCIENCE

RPW_BACKUP

RPW_OFF

Written

TC for turning off RPW is given in the SSS (see SSS-OB-030)

IW-FCP-003Switch OFF the RPW prime power interface (UNIT_A) via OBCP from the SAFE mode RPW_SAFE (prime/A)RPW_OFFWritten
IW-FCP-004Switch OFF the RPW redundant power interface (UNIT_B) via OBCP from the SAFE mode RPW_SAFE (redundant/B)RPW_OFFWritten
IW-FCP-010Boot RPW DBS in prime power interface (UNIT_A)RPW_OFFRPW_SAFE (prime/A)
Written
IW-FCP-011Boot RPW DBS in redundant power interface (UNIT_B)RPW_OFFRPW_SAFE (redundant/B)Written
IW-FCP-030Boot RPW DAS from EEPROM1 (default), EEPROM2, RAMRPW_SAFERPW_STANDBYWritten
IW-FCP-031Enter SERVICE mode and switch on RPW equipmentRPW_STANDBYRPW_SERVICE (with all equipement ON)Written
IW-FCP-032Enter SERVICE mode

RPW_STANDBY

RPW_SCIENCE

RPW_BACKUP

RPW_SERVICEWritten

duration of the procedure about 10s.

When coming from the STANDBY mode, all equipment are OFF.

IW-FCP-033Switch the converter (CONV)RPW_SERVICERPW_SERVICEWritten
IW-FCP-034BOOT LFR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootRPW_SERVICERPW_SERVICEWritten
IW-FCP-035BOOT THR from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootRPW_SERVICERPW_SERVICEWritten
IW-FCP-036BOOT TDS from EEPROM1 (default), EEPROM2 and RAM + Enabled Verif BootRPW_SERVICERPW_SERVICEWritten

IW-FCP-037

Switch ON BIASRPW_SERVICERPW_SERVICEWritten
IW-FCP-038PA Switch ONRPW_SERVICERPW_SERVICEWritten
IW-FCP-039SCM switch ONRPW_SERVICERPW_SERVICEWritten
IW-FCP-040Configure THR for the RPW SCIENCE SURVEY_NORMAL mode.RPW_SERVICERPW_SERVICEWrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.
IW-FCP-041Configure the Bias (mode, relay and currents) for the RPW SCIENCE mode.RPW_SERVICERPW_SERVICEWrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.
IW-FCP-042Enter in SCIENCE SURVEY_NORMAL submodeRPW_SERVICERPW_SCIENCEWritten

IW-FCP-043

Configure and execute the BIAS sweepRPW_SCIENCERPW_SCIENCEWritten
IW-FCP-044Internal Calibration for LFRRPW_SCIENCERPW_SCIENCEWrittenTNR-HFR must be set in specific mag. config during the LFR calibration, in order to check B measurements
IW-FCP-045BIAS CalibrationRPW_SCIENCERPW_SCIENCEWritten
IW-FCP-046Enter in SCIENCE SURVEY_BURST submodeRPW_SCIENCERPW_SCIENCEWritten
IW-FCP-047Configure THR for the RPW SCIENCE SURVEY_BURST mode. RPW_SCIENCERPW_SCIENCEWrittenThe default value for TC formal parameters shall correspond to the BURST-DEFAULT config.
IW-FCP-048Configure DPU and DAS + configure HK periodRPW_SERVICERPW_SERVICEWritten
RPW_SCIENCERPW_SCIENCE

RPW_BACKUP

RPW_BACKUP

IW-FCP-049Load common parameters of TDS

RPW_SERVICE

RPW_SERVICE

Written
RPW_SCIENCERPW_SCIENCE
RPW_BACKUPRPW_BACKUP
IW-FCP-050Configuration of TDS, LFR for SBM1 mode

RPW_SERVICE

RPW_SERVICE

WrittenThe default value for TC formal parameters shall correspond to the SBM1-DEFAULT config.
RPW_SCIENCERPW_SCIENCE
RPW_BACKUPRPW_BACKUP
IW-FCP-051Configuration of TDS, LFR for SBM2 mode

RPW_SERVICE

RPW_SERVICE

WrittenThe default value for TC formal parameters shall correspond to the SBM2-DEFAULT config.
RPW_SCIENCERPW_SCIENCE
RPW_BACKUPRPW_BACKUP
IW-FCP-052

Configure TDS LFM parameters

RPW_SERVICERPW_SERVICEWrittenThe default value for TC formal parameters shall correspond to the LFM-DEFAULT config.
IW-FCP-053Load calibration parameters for THR

RPW_SERVICE

RPW_SERVICE

Written
RPW_SCIENCERPW_SCIENCE
RPW_BACKUPRPW_BACKUP
IW-FCP-054Dump LFR, TDS, THR parameters

RPW_SERVICE

RPW_SERVICE

Written
RPW_SCIENCERPW_SCIENCE
RPW_BACKUPRPW_BACKUP
IW-FCP-055Enter in SCIENCE SURVEY_BACKUP submodeRPW_SERVICERPW_BACKUPWritten
IW-FCP-056Load common parameters of LFR

RPW_SERVICE

RPW_SERVICE

Written
RPW_SCIENCERPW_SCIENCE
RPW_BACKUPRPW_BACKUP
IW-FCP-057Enter in RPW STANDBY mode from any other mode (except OFF)

RPW_SAFE

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_STANDBYWrittenIf required, equipment units are automatically switched-off by the DPU before entering in the STANDBY mode.
IW-FCP-058Enter in SBM_DETECTION mode

RPW_SERVICE

RPW_SCIENCE

RPW_SBM_DETECTIONWritten
IW-FCP-059Configure TDS for the RPW SCIENCE SURVEY_NORMAL mode. RPW_SERVICERPW_SERVICEWrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.
IW-FCP-060Configure LFR for the RPW SCIENCE SURVEY_NORMAL mode. 

RPW_SERVICE

RPW_SERVICE

WrittenThe default value for TC formal parameters shall correspond to the NORMAL-DEFAULT config.
RPW_SCIENCERPW_SCIENCE

RPW_BACKUP

RPW_BACKUP
IW-FCP-061

Configure TDS for the RPW SCIENCE SURVEY_BURST mode.

RPW_SERVICE

RPW_SERVICE

Written
RPW_SCIENCERPW_SCIENCE
IW-FCP-062

Configure LFR for the RPW SCIENCE SURVEY_BURST mode.

RPW_SERVICE

RPW_SERVICE

Written
RPW_SCIENCERPW_SCIENCE
RPW_BACKUPRPW_BACKUP
IW-FCP-063Make enable the THR internal calibration

RPW_SCIENCE

RPW_SCIENCE

Written
RPW_BACKUPRPW_BACKUP
IW-FCP-064Go to SAFE mode (DBS) with TC_DPU_RESET command

RPW_STANDBY

RPW_SERVICE

RPW_SCIENCE

RPW_BACKUP

RPW_SAFEWritten
IW-FCP-260Dump DPU memory (TC_DPU_DUMP_MEMORY - Service 6)RPW_SAFERPW_SAFEWritten
RPW_SERVICERPW_SERVICE
RPW_SCIENCERPW_SCIENCE
RPW_BACKUPRPW_BACKUP
IW-FCP-XXXDump THR memory (TC_THR_DUMP_MEMORY - Service 6)All modes except RPW_STANDBYAll modes except RPW_STANDBY
To be written
IW-FCP-XXXDump LFR memory (TC_LFR_DUMP_MEMORY - Service 6)All modes except RPW_STANDBYAll modes except RPW_STANDBY
To be written
IW-FCP-XXXDump TDS memory (TC_TDS_DUMP_MEMORY - Service 6)All modes except RPW_STANDBYAll modes except RPW_STANDBY
To be written
IW-FCP-370Run a test connection (PUS, Service 17) with the TC_DPU_TEST_CONNECTION {ZIW00012} (i.e. "ping")

RPW_SAFE

RPW_SAFE

Written
RPW_STANDBYRPW_STANDBY
RPW_SERVICERPW_SERVICE







Contingency Recovery Procedures (CRP)

The table below gives the list of procedures specific to the contingency recovery operations.

NameDescriptionMode at startMode at endAuthor(s)StatusComments
IW-CRP-001Emergency Switch OFFAllRPW_OFF
To be written
IW-CRP-010Contingency ON procedures (UNIT A)RPW_OFFRPW_SAFE
To be written
IW-CRP-011Contingency ON procedures (UNIT B)RPW_OFFRPW_SAFE
To be written
IW-CRP-020Go in SAFE modeRPW_SCIENCERPW_SAFEWritten
IW-CRP-021

Phase back to Default Mode (i.e. to resume science after contingency)




To be written

Commissioning Procedures (COM)

The table below gives the list of procedures specific to the commissionning operations, including ANT and iBoom deployments, as well as the interference campaign.

NameDescriptionMode at startMode at endAuthor(s)StatusComments
IW-COM-XXX





IW-COM-XXXConfigure TDS with specific "single_ended" SURVEY_BURST mode configuration for the interference campaign.RPW_SCIENCE

RPW_SCIENCE

To be written
IW-COM-XXXConfigure TDS with specific "dipole" SURVEY_BURST mode configuration for the interference campaign.RPW_SCIENCERPW_SCIENCETo be written
IW-COM-XXXConfigure THR with specific config. for interference campaign

To be written
IW-COM-XXXConfigure LFR with specific config. for interference campaign

To be written








Open issues

IssuesCommentStatus
Compression activation/deactivation shall be added when configuring the sub-systems in SERVICE mode in some wayMight be a single procedure for this task
Need a procedure to enter in SBM_DETECTIONDone with IW-FCP-058Fixed
Does the formal parameter (FP) mechanism should be used for COM and CRP?

Need a procedure to enter in SERVICE mode from SCIENCEDone with IW-FCP-032Fixed
Do IW-FCP-001 and IW-FCP-002 can only contain the TC to switch-off the instrument?

Does IW-CRP-020 can be used nominally to enter in mode SAFE?The IW-FCP-064 can be used tooFixed